High voltage cable assemblies, High voltage cable configurations, Aerobell 168 high voltage connect at atomizer end – Ransburg Aerobell 168 Atex Approved 13350 User Manual
Page 36: Ransburg, Aerobell 168, High voltage connect at atomizer end
Contact Spring
HV Connector
HIGH VOLTAGE CABLE
ASSEMBLIES
General Instructions
1. When routing cable, ensure that no chaffing,
binding, or pulling on the cable will occur. Maintain
at least a 4-inch (100mm) bend radius. When
possible, sleeve cable with the appropriate sized
tubing for external cable protection. Torsion stress
should be minimized.
2. Considerations should be taken when routing
cables next to other cabling and fluid tubing. Be
cognizant of the placement of such cable near
control wires and fluid lines. Follow NEC or EN
standard wiring standards where applicable.
Separation of AC, control wiring, and fluid tubing
is advisable.
3. To ensure that all cable connections are clean
and free of foreign materials, wipe with Naphtha.
This also applies to the cascade, splitter, and
applicator connectors.
HIGH VOLTAGE CABLE
CONFIGURATIONS
There are two (2) high voltage cable assemblies
available:
A13386-XX is a shielded cable and is the most
flexible. It is available in several lengths per the
“Accessories” chart in the “Parts Identification”
section.
A13348-XX is a resin core conductor cable with a
polyethylene jacket and an exterior Nylon sleeve.
It comes pre-assembled with banana jacks at
each end.
4. Ensure that no conductive sponges are used
in any connector!
5. A13386-XX or A13348-XX cables are not to be
modified in the field. To do so will void any and
all warranties that may exist.
Do not use any di-electric grease or oil
on any of the cable connections or on the ca-
bles themself. Damage to cables will occur.
C A U T I O N
!
Installation of A13348-XX Cable
Insert resistor (Shipped seperately with Applicator)
A13382-00 into the applicator end of the cable.
AEROBELL 168
HIGH
VOLTAGE CONNECT AT
ATOMIZER END
Make sure the contact spring is outward as shown
below
Insert the high voltage connector on the cable end
into the applicator part marked with “HV”. Tighten
the connector in place.
A13382
A13348
CASCADE END
APPLICATOR END
CASCADE END
APPLICATOR END
Aerobell 168 - Installation
Ransburg
LN-9247-13
33