Bearing Air

Use tubing (clear, see-through, nylon, natural) to

connect a properly filtered air source to the bearing

air fitting on the manifold. It is recommended to

use tubing (clear, see- through) for bearing air

so that any contamination that gets past the final

bearing air filter will be apparent. Also refer to the

previous “Caution”.

Under the “Operation” section which follows, there

is a “Caution” regarding bearing damage if the

turbine is run while bearing air is off. Since the

turbine must not be operated without first turning

on bearing air, it is required to provide some

means of assuring the presence of bearing air

before turning the turbine “On.” One method is

by interlocking the turbine drive air to the bearing

air (i.e., with an air piloted valve).

Brake Air

Turbine Air

Turbine drive air must be interlocked with paint flow.

Damage to spindle will occur if paint is triggered

without the bell cup spinning. It is recommended

that the bell cup is spinning at least 10,000 rpm

before any fluid is turned on.

FLUID CONNECTIONS

See pages 23 & 24 for connections. See the

following “Note”.

†

If the coating material used is heated,

check the maximum rated temperature

for the fluid tubing used. Polyethylene

tubing (H-2338 and H-2339) is rated for

a maximum of 80°F (27°C). Nylon tubing

(H-2340 and H-2341) is rated for 200°F

(95°C) maximum.

W A R N I N G

!

†

Arcing/fire hazard exist if ungrounded

metal connections (air or fluid) are used in

the spray area. Use plastic non-conductive

connections, or ensure metal connections

are at ground potential.

†

Provisions should also be made to as-

sure bearing air remains on during the coast

down period when turbine air is turned off.

See “Specifications” in the “Introduction”

section of this manual

†

Brake air is used to slow the turbine

when changing speed. It is recommend-

ed that the brake air turbine drive air be

interlocked.

NOTE

NOTE

C A U T I O N

!

†

Do not use PTFE tape or pipe dope on

any air beyond the final air filter for BEARING

AIR. The tape or dope may break free and

cause plugging of the turbine air bearings,

and result in turbine failure. See pages 23 &

24 for tubing connections and sizes.)

C A U T I O N

!

†

Any user supplied air hoses must be rat-

ed at a minimum working pressure of 100

psig (7 bar)

C A U T I O N

!

†

Any user supplied fluid hoses must be

rated at a minimum working pressure of 150

psig (10 bar)

C A U T I O N

!

Aerobell 168 - Installation

Ransburg

LN-9247-13

31

Advertising