Hose specifications, Ransburg – Ransburg Aerobell 168 Atex Approved 13350 User Manual

Page 29

Advertising
background image

Paint Supply @ Applicator

1/4” O.D. Tube Fitting

Paint Supply @Valve Manifold

5mm I.D. x 8mm O.D. PFA (.197” I.D. x 5/16” O.D.)

Turbine Supply @ Applicator

6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)

Turbine Braking Air Supply @ Applicator 6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)
Bearing Air Supply @ Applicator

6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)

Bearing Air Return @ Applicator

2.7mm I.D. x .4mm O.D. Nylon (.107 “ I.D. x 5/32” O.D.)

Shaping Air 1 @ Applicator

6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)

Sharping Air 2 @ Applicator

6mm I.D. x 8mm O.D. Nylon (.236” I.D, x 5/16” O.D.)

Interior and Bell Cup Exterior Rinsing

Air/Solvent

1/16” I.D. x 3/32” O.D. PFA

Dump @ Valve Manifold

5mm I.D. x 8mm O.D. PFA (.197” I.D. x 5/16” O.D.)

Pilot for all Microvalves

2.7mm I.D. x .4mm I.D. Nylon (.107 “ I.D. x 5/32” O.D.)

Interior and Bell Cup Exterior Rinsing

Air/Solvent Supply @ Valve Manifold

5mm I.D. x 8mm O.D. PFA (.197” I.D. x 5/16” O.D.)

W A R N I N G

!

†

Arcing/fire hazard exist if ungrounded

metal connections (air or fluid) are used in

the spray area. Use plastic non-conductive

connections, or ensure metal connections

are at ground potential.

PFA* hoses must never be replaced with

Nylon hoses. Only Polyamide Nylon hoses

can be used for air connections. Polyure-

thane hoses are prohibited.

* PFA = Ultra Pure Polytetrafluoroethylene

Function

Hose Characteristic

HOSE SPECIFICATIONS

†

Any user supplied air hoses must be rat-

ed at a minimum working pressure of 100

psig (7 bar)

C A U T I O N

!

†

Any user supplied fluid hoses must be

rated at a minimum working pressure of 150

psig (10 bar)

C A U T I O N

!

Aerobell 168 - Installation

Ransburg

LN-9247-13

26

Advertising