SURVEY OF TESTS TABLE

Kind of Test

Requirements

Review & Testing

Interval

• In this context, especially the disconnection threshold,

the overcurrent I

ü

and the minimum voltage U

min

shall

be defined and documented with respect to operational

and local conditions.

• Ventilation must be properly interlocked with high

voltage power supply.

• Forced ventilation must be proved to be working

effectively.

• The disconnection threshold I

ü

shall be defined and

documented with respect to operational and local

conditions.

• It shall be tested if the high voltage is disconnected in

case of inadmissible increase of the operational current

I

b

and if the disconnection threshold I

ü

is reached.

• In this context, the disconnection threshold I

ü

defined

during the initial test shall be checked.

• A disconnection threshold I

ü

giving rise to expect an

occurrence of hazardous discharges or flashover

between parts under high voltage and earthed parts

of the plant in case the safety distance drops below

the permissible limit, is not permitted.

• Validate safety circuits are performing as designed.

• Discharge energy must be less than 300 mJ prior to

reaching the parts.

• Use non-flamable cleaning agents if possible.
• Those used for equipment flushing should have flash

points equal to or higher than those of the coating

material.

• Those solvents used for cleaning must have a flash

point at minimum of 5°C (9°F) greater than the am-

bient temperature. It is the end users responsibility

to insure this condition is met.

TESTS OF THE STATIONARY EQUIPMENT

The tests shall be carried out for each single spraying system. The test shall be carried out by skilled persons

and include the tests according to this table and the internal notes.

APPENDIX A

Protection against ignition of

cleaning agents

Protection against too

high discharge energy

Safe disconnection of high

voltage shall be tested for

voltage-controlled and con-

stant voltage operation

Safe disconnection of high

voltage shall be tested for

voltage-controlled and con-

stant voltage operation

Effectivity of forced

ventilation (exhaust

air systems)

The stationary equipment

for electrostatic coating

with ignitable liquid coating

materials shall be tested for

occupationally safe state

Every 12

months

Continuously

At every

switch on

Monthly

Weekly

Before each

cleaning

Aerobell 168 - Appendix

Ransburg

LN-9247-13

99