Disassembly procedures (15mm), Ransburg, Disassembly procedures – Ransburg Aerobell 168 Atex Approved 13350 User Manual
Page 54: Step 1, Step 2
Advertising
![background image](/manuals/348100/54/background.png)
DISASSEMBLY PROCEDURES
(15mm Bell Cup and Shape Air Ring)
Mean time to repair entire assembly
is 60 Minutes.
Step 1
Place the Aerobell 168 on a clean sta-
ble working surface or mount.
Remove the Shaping Air Shroud by
hand (no tool required).
NOTE
Step 2
Aerobell 168 - Maintenance
Ransburg
LN-9247-13
51