Operating characteristics and specifications, Ransburg, Aerobell 168 - introduction – Ransburg Aerobell 168 Atex Approved 13350 User Manual
Page 18
![background image](/manuals/348100/18/background.png)
OPERATING CHARACTERISTICS AND SPECIFICATIONS
* When measured with Ransburg meter 76652
Weight
Atomizer (Post Mount 65mm)
2.7 kg (6 lbs.)
Atomizer (Robot Mount /Valves/65mm) 4.4 kg (9.7 lbs.)
Voltage
Maximum Operating Voltage
90 kV
Maximum Operating Current
80 uA
Turbine
Recommended Turbine Speed
15 to 60 Krpm
Turbine Type
Impulse - Rear Exhaust
Speed Readout Pickup
Magnetic or Light Source (2 pulse/rev.)
Paint
Flow Rate
50-500 cm
3
/min max. (depending on paint)
Normal Supply Pressure
6 to 8 bar (90 psi to 120 psi)
Maximum Pressure
10 bar (150 psi)
Viscosity
20 to 40 Seconds - Ford Cup # 4
Viscosity
20 to 45 Seconds - AFNOR Cup # 4
Paint Resistivity
0.1 MW. to *
Air Pressure
Microvalve Pilot
4.9 bar (Min.) - 10 bar (Max.) (75-150 psi)
Bearing Air
5.5 bar (Min.) - 7 bar (Max.) (80 - 100 psi)
Shaping Air
7 bar Max. (100 psi)
Brake Air
4 bar Min. - 7 bar Max. (60-100 psi)
Change Time
Rotator Atomizer
Less than 5 minutes
Bell
Less than 5 minutes
Distance
Target
152 - 305mm (6-12 inches)
Compressed Air Quality
See Filter Section
Air Consumption
Bearing Air
57 - 85 slpm (2-3 scfm)
Shaping Air 1
75 to 600 NI/min (2.65-21.2 scfm)
Shaping Air 2
75 to 600 NI/min (2.65-21.2 scfm)
Turbine
See Charts
∞
Aerobell 168 - Introduction
Ransburg
LN-9247-13
15