OPERATING CHARACTERISTICS AND SPECIFICATIONS

* When measured with Ransburg meter 76652

Weight

Atomizer (Post Mount 65mm)

2.7 kg (6 lbs.)

Atomizer (Robot Mount /Valves/65mm) 4.4 kg (9.7 lbs.)

Voltage

Maximum Operating Voltage

90 kV

Maximum Operating Current

80 uA

Turbine

Recommended Turbine Speed

15 to 60 Krpm

Turbine Type

Impulse - Rear Exhaust

Speed Readout Pickup

Magnetic or Light Source (2 pulse/rev.)

Paint

Flow Rate

50-500 cm

3

/min max. (depending on paint)

Normal Supply Pressure

6 to 8 bar (90 psi to 120 psi)

Maximum Pressure

10 bar (150 psi)

Viscosity

20 to 40 Seconds - Ford Cup # 4

Viscosity

20 to 45 Seconds - AFNOR Cup # 4

Paint Resistivity

0.1 MW. to *

Air Pressure

Microvalve Pilot

4.9 bar (Min.) - 10 bar (Max.) (75-150 psi)

Bearing Air

5.5 bar (Min.) - 7 bar (Max.) (80 - 100 psi)

Shaping Air

7 bar Max. (100 psi)

Brake Air

4 bar Min. - 7 bar Max. (60-100 psi)

Change Time

Rotator Atomizer

Less than 5 minutes

Bell

Less than 5 minutes

Distance

Target

152 - 305mm (6-12 inches)

Compressed Air Quality

See Filter Section

Air Consumption

Bearing Air

57 - 85 slpm (2-3 scfm)

Shaping Air 1

75 to 600 NI/min (2.65-21.2 scfm)

Shaping Air 2

75 to 600 NI/min (2.65-21.2 scfm)

Turbine

See Charts