Vibration Noise

If the Aerobell 168 is vibrating or making an un-

usually loud noise, it usually means there is an

imbalance situation. The atomizer bell may have

dried paint on it, or the bell may be physically

damaged, or there may be paint trapped between

the bell and shaft preventing the bell from properly

seating. If any of these conditions exist, they

must

be corrected. Excessive imbalance caused by one

of these conditions may result in bearing damage

and turbine failure. Warranty

DOES NOT cover

failure caused by imbalanced loading conditions.

To determine if the bell is dirty or damaged, re-

move the bell and turn the turbine on. If the noise

is eliminated, the bell cup is the problem. If the

noise continues, the turbine may be damaged

and should be inspected. Excessive air required

to achieve same speed may indicate a faulty

or contaminated turbine.

DO NOT continue to

operate a noisy turbine.

PREVENTIVE

MAINTENANCE

(See “Preventive Maintenance Schedule”)

Daily/Weekly Maintenance

†

Due to the close proximity of high voltage to

ground potential, a schedule must be developed

for equipment maintenance (cleanliness).

†

Verify that high voltage is OFF and that shap-

ing air, bearing air, and turbine drive air are ON.

†

Open the dump valve, if equipped, flushing

all paint from the supply lines and valve module.

†

Open the solvent valve, if equipped, flushing

all paint from the fluid tube and through the at-

omizer bell assembly.

†

Verify that high voltage is OFF, turbine drive

air is OFF, and that the bell cup has stopped

spinning. The bearing air and shaping air should

remain ON.

†

Clean all external surfaces of the applica-

tor using a lint-free rag dampened with solvent.

External surfaces include the shroud and valve

module.

†

After cleaning, all conductive residue must be

removed using a non-conductive solvent. since

electrostatic equipment is involved, these sol-

vent should also be non-polar.

†

Inspect bell cup for nicks, dents, heavy

scratches, or excessive wear. Replace if nec-

essary.

W A R N I N G

!

†

Those solvents used for cleaning must

have a flash point at minimum of 5°C (9°F)

greater than ambient temperature. It is the

end users responsibility to insure this condi-

tions is met. Also, since electrostatic equip-

ment is involved, these solvents should

be non-polar. Example of non-flammable,

non-polar solvents for wipe down are: amyl

acetate, methyl amyl acetate, high flash

naphtha, and mineral spirits.

a. If using a rag to hand wipe the Aerobell,

turbine air should be off, but leave shaping

air on. 70-100 SLPM for shaping air is rec-

ommended.

b. Do not use conductive solvents such as .

MEK to clean the Aerobell 168.

Aerobell 168 - Maintenance

Ransburg

LN-9247-13

42

Advertising