Pre-filter, removes coarse amounts of oil, moisture

and dirt. Used upstream of HAF-508 pre-filter (used in

systems with poor air quality.

Pre-filter, coalescing type, 136 SCFM, 98.5% efficien-

cy particulate removal .3 to .6 micron, max. aerosol

passed 1.0 micron, max. solid passed .4 micron

(dependent upon SCFM requirement per applicator,

one HAF-508 can be used with up to three Aerobell

168 assemblies).

Bearing air filter, coalescing type,19 SCFM, 99.995%

efficiency particulate removal .3 to .6 micron, max.

Aerobell 168 passed .6 micron max. solid passed .2

micron (one per Aerobell 168)

†

Air must be properly filtered to ensure

extended turbine life and to prevent contam-

ination of the paint finish. Air which is not

adequately filtered will foul the turbine air

bearings and cause turbine failure. The cor-

rect type filters musts be used in an Aerobell

168 system. The filter elements must be

replaced regular schedule to assure clean

air.

†

It is the user’s responsibility to ensure

clean air at all times. Turbine failure result-

ing form contaminated air will not be cov-

ered under warranty. If other filters are incor-

porated in the system, the filters to be used

must have filtering capacities equal or better

than those shown in “Air Filtration Require-

ments Charts.”

†

The user must ensure the bearing air

supply is not inadvertently turned off while

the Aerobell 168 air motor is turning. This

will cause air bearing failure.

†

Each applicator must have its own filter

for bearing air. Recommended: RPM-418

or equivalent.

AIR FILTRATION REQUIREMENTS

Ransburg Filter

Model No.

Description / Specifications

Replacement

Element Part No.

HAF-15 Element One

HAF-38 Elements, Carton of 4

RPM-33 Elements, Carton of 8

HAF-503

HAF-508

RPM-418