Air filtration requirements, Ransburg – Ransburg Aerobell 168 Atex Approved 13350 User Manual
Page 30
![background image](/manuals/348100/30/background.png)
Pre-filter, removes coarse amounts of oil, moisture
and dirt. Used upstream of HAF-508 pre-filter (used in
systems with poor air quality.
Pre-filter, coalescing type, 136 SCFM, 98.5% efficien-
cy particulate removal .3 to .6 micron, max. aerosol
passed 1.0 micron, max. solid passed .4 micron
(dependent upon SCFM requirement per applicator,
one HAF-508 can be used with up to three Aerobell
168 assemblies).
Bearing air filter, coalescing type,19 SCFM, 99.995%
efficiency particulate removal .3 to .6 micron, max.
Aerobell 168 passed .6 micron max. solid passed .2
micron (one per Aerobell 168)
Air must be properly filtered to ensure
extended turbine life and to prevent contam-
ination of the paint finish. Air which is not
adequately filtered will foul the turbine air
bearings and cause turbine failure. The cor-
rect type filters musts be used in an Aerobell
168 system. The filter elements must be
replaced regular schedule to assure clean
air.
It is the user’s responsibility to ensure
clean air at all times. Turbine failure result-
ing form contaminated air will not be cov-
ered under warranty. If other filters are incor-
porated in the system, the filters to be used
must have filtering capacities equal or better
than those shown in “Air Filtration Require-
ments Charts.”
The user must ensure the bearing air
supply is not inadvertently turned off while
the Aerobell 168 air motor is turning. This
will cause air bearing failure.
Each applicator must have its own filter
for bearing air. Recommended: RPM-418
or equivalent.
AIR FILTRATION REQUIREMENTS
Ransburg Filter
Model No.
Description / Specifications
Replacement
Element Part No.
HAF-15 Element One
HAF-38 Elements, Carton of 4
RPM-33 Elements, Carton of 8
HAF-503
HAF-508
RPM-418
C A U T I O N
!
NOTE
Aerobell 168 - Installation
Ransburg
LN-9247-13
27