Installation of A13386-XX Cable
Insert resistor (Shipped seperately with Applicator)
A13382 into the part of the applicator marked HV.
The spring should be inserted first into the part.
Using the applicator end of the cable loosen the
strain relief and remove the cable from the High
Voltage Connector. Thread and tighten the High
Voltage Connector into the Port marked “HV” on
the back of the applicator. Insert the cable through
the strain relief until contact is made with the re-
sistor. Tighten the strain relief to secure the cable.
APPLICATOR END
CASCADE END
A13382-00
A13386-XX
AEROBELL 168
CASCADE CONNECTION
Insert the cable end of the A13386-XX cable into
the external cascade as shown.
Insert the cascade of the A13348-XX cable end
into the external cascade as shown.
A13386-XX
Aerobell 168 - Installation