Configuring rate limiters, Figure 32: acl port configuration – LevelOne GSW-4876 User Manual

Page 100

Advertising
background image

C

HAPTER

4

| Configuring the Switch

Configuring Security

– 100 –

Figure 32: ACL Port Configuration

C

ONFIGURING

R

ATE

L

IMITERS

Use the ACL Rate Limiter Configuration page to define the rate limits

applied to a port (as configured either through the ACL Ports Configuration

menu (

page 98

) or the Access Control List Configuration menu (

page 101

).

P

ATH

Advanced Configuration, Security, Network, ACL, Rate Limiters

P

ARAMETERS

These parameters are displayed:

Rate Limiter ID - Rate limiter identifier. (Range: 0-14; Default: 1)

Rate - The threshold above which packets are dropped.

(Options: 0-100 pps, or 0, 100, 2*100, 3*100, ... 1000000 kbps)
Due to an ASIC limitation, the enforced rate limits are slightly less than

the listed options. For example: 1 Kpps translates into an enforced

threshold of 1002.1 pps.

W

EB

I

NTERFACE

To configure rate limits which can be applied to a port:

1.

Click Advanced Configuration, Security, Network, ACL, Rate Limiters.

2.

For any of the rate limiters, select the maximum ingress rate that will
be supported on a port once a match has been found in an assigned

ACL.

3.

Click Save.

Advertising