Running Cable Diagnostics

– 281 –

R

UNNING

C

ABLE

D

IAGNOSTICS

The VeriPHY page is used to perform cable diagnostics for all ports or

selected ports to diagnose any cable faults (short, open, etc.) and report

the cable length.

P

ATH

Diagnostics, VeriPHY

P

ARAMETERS

These parameters are displayed on the VeriPHY Cable Diagnostics page:

Port – Diagnostics can be performed on all ports or on a specific port.

Cable Status – Shows the cable length, operating conditions and

isolates a variety of common faults that can occur on Category 5

twisted pair cabling.

W

EB

I

NTERFACE

To run cable diagnostics:

1.

Click Diagnostics, VeriPHY.

2.

Select all ports or indicate a specific port for testing.

3.

Click Start.

If a specific port is selected, the test will take approximately 5 seconds. If

all ports are selected, it can run approximately 15 seconds. When

completed, the page refreshes automatically, and you can view the cable

diagnostics results in the cable status table. Note that VeriPHY is only

accurate for cables 7 - 140 meters long.

Ports will be linked down while running VeriPHY. Therefore, running VeriPHY

on a management port will cause the switch to stop responding until

testing is completed.