Displaying rmon alarm settings, Figure 118: rmon history overview – LevelOne GSW-4876 User Manual

Page 247

Advertising
background image

C

HAPTER

5

| Monitoring the Switch

Displaying Information on RMON

– 247 –

W

EB

I

NTERFACE

To display RMON historical samples, click Monitor, Security, Switch, RMON,

History.

Figure 118: RMON History Overview

D

ISPLAYING

RMON

A

LARM

S

ETTINGS

Use the RMON Alarm Overview page to display configured alarm settings.

P

ATH

Monitor, Security, Switch, RMON, Alarm

P

ARAMETERS

These parameters are displayed:

ID – Index of Alarm control entry.

Interval – Interval in seconds for sampling and comparing the rising

and falling threshold.

Variable – MIB object to be sampled.

Sample Type – The method of sampling the selected variable and

calculating the value to be compared against the thresholds. For more

information, see

"Configuring RMON Alarms" on page 81

.

Value – The value of the statistic during the last sampling period.

Startup Alarm – The alarm that may be triggered when this entry is

first set to valid.

Rising Threshold – If the current value is greater than the rising

threshold, and the last sample value was less than this threshold, then

an alarm will be generated.

Rising Index – The index of the event to use if an alarm is triggered

by monitored variables crossing above the rising threshold.

Falling Threshold – If the current value is less than the falling

threshold, and the last sample value was greater than this threshold,

then an alarm will be generated.

Falling Index – The index of the event to use if an alarm is triggered

by monitored variables crossing below the falling threshold.

Advertising