The switch provides power saving methods including powering down the

circuitry for port queues when not in use.

R

EDUCING

P

OWER

TO

I

DLE

Q

UEUE

C

IRCUITS

Use the EEE Configuration page to configure Energy Efficient Ethernet

(EEE) for specified queues.

P

ATH

Advanced Configuration, Power Reduction, EEE

C

OMMAND

U

SAGE

EEE works by powering down circuits when there is no traffic. When a

port gets data to be transmitted all relevant circuits are powered up.

The time it takes to power up the circuits is call the wakeup time. The

default wakeup time is 17 µs for 1 Gbps links and 30 µs for other link

speeds. EEE devices must agree upon the value of the wakeup time in

order to make sure that both the receiving and transmitting devices

have all circuits powered up when traffic is transmitted. The devices

can exchange information about the device wakeup time using LLDP

protocol.
To maximize power savings, the circuit is not started as soon as data is

ready to be transmitted from a port, but instead waits until 3000 bytes

of data is queued at the port. To avoid introducing a large delay when

the queued data is less then 3000 bytes, data is always transmitted

after 48 µs, giving a maximum latency of 48 µs plus the wakeup time.

P

ARAMETERS

These parameters are displayed:

Port – Port identifier.

Enabled – Enables or disables EEE for the specified port.

W

EB

I

NTERFACE

To configure the power reduction for idle queue circuits:

1.

Click Configuration, Power Reduction, EEE.

2.

Select the circuits which will use EEE.

3.

Click Save.