15

INSTALLATION

STANDARD INSTALLATION ONLY

STANDARD INSTALLATION ONLY

CONTINUED...

POSITION THE GATE BRACKET

NOTE: It may be necessary to attach horizontal reinforcement to the gate before

attaching the gate bracket.

1

Position the operator arm onto the output shaft so that the pin slides into the

slot.

2

Measure 46 inches along the gate length from the gate hinge center.

3

Measure 27.5 inches up from the concrete pad to the gate hinge position on the

gate as shown.

4

Make sure the operator arm is level and tack weld the gate bracket in this

position. Use the set screws on the arm to temporarily hold the arm in place

while determining the correct measurements.

Slot

Output Shaft

Pin

Gate Hinge

Center

Set Screws

46"

Tack weld

2

4

1

ADJUST THE OPERATOR ARM LENGTH

NOTE: The length of the arm can be adjusted if necessary. If adjusting the length,

ensure that both sections of the arm are adjusted proportionally. Use the set screws

on the arm to temporarily hold the arm in place while determining the correct

measurements.

1

Close the gate and measure the distance of the operator arm from the gate

bracket to the output shaft center. This distance is E.

2

Open the gate 90° (do not allow arms to scissor when open). Measure both

sections of the arm (D and C). The arm lengths are correct as long as C+D=E

(arm should be perpendicular to the gate in the open position as shown).

Proceed to page 18.

TOP VIEW - CLOSED GATE

E

Output Shaft

Set Screws

1

Output Shaft

Gate Open

90°

Set Screws

C

D

TOP VIEW - OPEN GATE

2

3

27.5"

Advertising