Wiring, Connect batteries continued – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 25

Advertising
background image

23

CONNECT BATTERIES

WIRING

The batteries are charged in the circuit by the integrated transformer. The batteries

are for battery backup or solar installation. The 33AH application requires the 33AH

wire harness (Model K94-36596) and an additional battery tray (Model K10-36183)

to allow more space in the enclosure. The heater option cannot be used with the

33AH battery application.

1

Locate the J15 plug on the control board and disconnect it.

2

Connect the white jumper from the 33AH wire harness kit between the

positive (+) terminal of one battery and the negative (-) terminal of the

other battery.

3

Connect one end of the red (+) wire from the 33AH wire harness kit to the

red wire from the J15 plug as shown. Connect the other end of the red (+)

wire to the positive (+) terminal on the battery as shown.

4

Connect one end of the black (-) wire from the 33AH wire harness kit to the

black wire from the J15 plug as shown. Connect the other end of the

black (-) wire to the negative (-) terminal on the battery as shown.

5

Turn ON AC power to the operator.

6

Turn ON the AC power switch on the operator.

7

Reconnect the J15 plug to the control board. NOTE: You may see a small

spark when plugging the J15 plug into the board.

33AH BATTERIES

CONNECT BATTERIES CONTINUED...

Red (+) wire

from new wire

harness kit

Red (+)

Black (-)

Black (+) wire

from new wire

harness kit

33AH Batteries

+

+

White jumper from

new wire harness kit

J15 Plug

Advertising