Maintenance, Maintenance chart, Batteries – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 50

Advertising
background image

48

NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator.

Using a digital voltmeter, verify that the incoming voltage to the operator is

within ten percent of the operator’s rating.

MAINTENANCE CHART

Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control board and

DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.

MAINTENANCE CHART + BATTERIES

MAINTENANCE

DESCRIPTION

TASK

CHECK AT LEAST ONCE EVERY

MONTH

6 MONTHS

3 YEARS

Entrapment Protection Devices

Check and test for proper operation

X

Warning Signs

Make sure they are present

X

Manual Disconnect

Check and test for proper operation

X

Sprockets and Chains

Check for excessive slack and lubricate

X

Gate

Inspect for wear or damage

X

Accessories

Check all for proper operation

X

Electrical

Inspect all wire connections

X

Chassis Mounting Bolts

Check for tightness

X

Operator

Inspect for wear or damage

X

Batteries

Replace

X

BATTERIES

Batteries will degrade over time depending on temperature and usage. The operator

alarm will beep 3 times with a command if the battery is low. Batteries do not

perform well in extremely cold temperatures. For best performance, the batteries

should be replaced every 3 years. Use only LiftMaster part 29-NP712 for

replacement batteries. The operator comes with two 7AH batteries. Two 33AH

(A12330SGLPK), 33AH Battery Harness (K94-36596) with additional battery tray

(K10-36183) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly.
NOTE: If your application includes a heater, two 33AH will not fit into the operator

enclosure.

Advertising