Troubleshooting, Input leds, Control board leds continued – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 43: Diagnostic codes leds status leds

Advertising
background image

41

INPUT LEDS

OPEN INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

CLOSE INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

STOP INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

FIRE DEPT

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

OPEN SAFETY

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

CLOSE SAFETY

INPUT

OFF

Input inactive

ON

Input active

BLINK

Input active on other operator

CONTROL BOARD LEDS

TROUBLESHOOTING

CONTROL BOARD LEDS CONTINUED...

YELLOW DIAGNOSTIC LED

# BLINKS

MEANING

CORRECTION

2 BLINKS

ID resistor failure

Check ID resistor wiring, clear limit

settings and reset limits

3 BLINKS

Exceeded Maximum

Run Timer

Check gate travel, if necessary adjust

force setting

5 BLINKS

RPM (obstruction)

Check for obstruction, if necessary

adjust force setting

6 BLINKS

Current (obstruction) Check for obstruction, if necessary

adjust force setting

7 BLINKS

Position failure

Check gate travel, clear limit settings

and reset limits

12 BLINKS

Loop Error

One of the loops is in error. Refer to the

loop detector to determine the error.

RED DIAGNOSTIC LED

# BLINKS

MEANING

CORRECTION

2 BLINKS

Current Sense

Motor control circuit fault, replace

control board

3 BLINKS

FET Failure

Motor control circuit fault, replace

control board

4 BLINKS

RAM Failure

Memory failure, replace control board

5 BLINKS

Flash Memory

Failure

Memory failure, replace control board

6 BLINKS

EEPROM Failure

Memory failure, replace control board

7 BLINKS

Watchdog Failure

Controller failure, replace control

board

8 BLINKS

Brownout

Check power harness or line voltage

9 BLINKS

Fail

Control Board failure

10-14 BLINKS

Software Failure

Cycle power to the control board. If

continues replace control board.

DIAGNOSTIC CODES LEDS

STATUS LEDS

INPUT

POWER

OFF

OFF state

ON

AC charger or Solar power available

BATT

CHARGING

OFF

Not charging

ON

Trickle charge

FAST BLINK (2 blinks

per second)

High current charge

SLOW BLINK (1 blink

every 2 seconds)

Medium charge

TIMER

OFF

The timer is disabled

ON

The timer is enabled

MEDIUM BLINK (1

blink per second)

The timer is running

FAST BLINK (2 blinks

per second)

The timer is paused

FASTEST BLINK (8

blinks per second)

The timer is cancelled

GATE

MOVING

OFF

The gate is stopped

ON

The gate is opening or closing

MEDIUM BLINK (1

blink per second)

Operator is in E1 (single entrapment)

FASTEST BLINK (8

blinks per second)

The operator is in E2 (double entrapment)

BATT LOW

OFF

No battery error

ON

Battery low

MEDIUM BLINK (1

blink per second)

Battery critically low

FAST BLINK (2 blinks

per second)

Battery disconnected error (seen in solar

application, motion is inhibited)

FASTEST BLINK (8

blinks per second)

Battery over voltage/over current error

ACC PWR

OVLD

OFF

OFF state

ON

Accessory overload protector opened