MANUAL DISCONNECT

Press the reset switch to RESET/DISCONNECT. Release the handle on the operator arm

to allow the gate to be opened and closed manually. On a dual gate application the

handle must be released on both operators. To resume normal function tighten the

handle by pushing it down.

RESET SWITCH

The reset switch is located on the front of the operator and serves several functions.
Toggling the reset switch will stop a moving gate during a normal open/close cycle,

like a stop button. The operator does not need to be reset after doing this. The reset

switch will disable the gate in the present position and will energize the solenoid lock

for two minutes and disable the maglock for two minutes.

OPERATOR ALARM

If a contact sensor detects an obstruction twice consecutively the alarm will sound (up

to 5 minutes) and the operator will need to be reset. If a command is given after the

initial 5 minutes the operator will beep. The operator alarm will beep 3 times with a

command if the battery is low.
When the inherent force of the operator (RPM/current sensor) detects the following

(twice consecutively) the alarm will sound (up to 5 minutes) and the operator will

need to be reset:
A. The operator arm or gate is incorrectly installed.
B. The gate does not meet specifications.
C. Gate hinges are too tight or broken and the gate is not moving freely.
D. The gate is moving and a car pushes the gate.
E. A foreign object is on the gate frame while the gate is moving.
F. The gate hits the driveway or curb and gets stuck or bent in an awkward

position.

Remove any obstructions. Press the reset button to shut off the alarm and reset

the operator. After the operator is reset, normal functions will resume.

REMOTE CONTROL

SINGLE BUTTON CONTROL (SBC) FUNCTIONALITY

Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open

the gate. During the open cycle another activation of the remote control will stop the

gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will

close the gate. If the remote control is activated while the gate is closing, the gate will

stop and the next activation will open the gate.

HEATER (IF APPLICABLE)

The operator may have a heater installed, depending on the model purchased. The

heater must be powered by 120 Vac ONLY. If the heater switch is left in the “ON”

position, the heater will turn on at approximately 40°F (4°C) and will turn off at

approximately 60°F (16°C).

!

!

!

!

!

!

A

D

E

F

B

C

MANUAL DISCONNECT + RESET SWITCH + OPERATOR ALARM + REMOTE CONTROL +

HEATER (IF APPLICABLE)

OPERATION

Manual Disconnect

Handle

RESET/DISCONNECT

NORMAL OPERATION

Heater (if applicable)

120 Vac ONLY