Installation, Compact installation only continued – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 19

Advertising
background image

17

INSTALLATION

COMPACT INSTALLATION ONLY

COMPACT INSTALLATION ONLY CONTINUED...

SHORTEN THE OPERATOR ARM

For a compact installation the operator arm will have to be shortened.

1

Take the operator arm apart and remove the inner sleeves from the outer

tubing.

2

Cut the outer tubing of the operator arm sections to the lengths shown.

3

Put the arm back together and adjust the arm to the measurements as

shown. Use the set screws on the arm to temporarily hold the arm in place

while determining the correct measurements.

1

2

3

long arm section

short arm section

CUT

CUT

CUT

10”

22”

4”

20”

4”

Set Screws

23”

25-1/2”

POSITION THE GATE BRACKET

NOTE: It may be necessary to attach horizontal reinforcement to the gate before

attaching the gate bracket. Use the set screws on the arm to temporarily hold the

arm in place while determining the correct measurements.

1

Position the operator arm onto the output shaft so that the pin slides into

the slot.

2

Measure 33 inches along the gate length from the gate hinge center.

3

Measure 27.5 inches up from the concrete pad to the gate hinge position on

the gate as shown.

4

Make sure the operator arm is level and tack weld the gate bracket in this

position.

Set Screws

2

33”

Gate Hinge

Center

4

Tack weld

Slot

Output Shaft

Pin

1

3

27.5”