Connect the entrapment protection device to the EYES EDGE terminal on the

control board:

• Close Photoelectric Sensor Entrapment Protection: Connect wires from the

photoelectric sensors to the Inputs on the CLOSE EYES/INTERRUPT terminal.

• Close Edge Entrapment Protection: Connect wires from the entrapment

protection device to the Inputs on the CLOSE EDGE terminal.

• Open Entrapment Protection: Connect wires from the entrapment protection

device to the Inputs on the OPEN EYES/EDGE terminal.

NOTE: Refer to the “Wiring Accessories to the Control Board” section on page 33.

WIRE THE ENTRAPMENT PROTECTION DEVICES + EARTH GROUND ROD

WIRING

To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may

come near a moving gate.

• Locate entrapment protection devices to protect in BOTH the open and close

gate cycles.

• Locate entrapment protection devices to protect between moving gate and

RIGID objects, such as posts or walls.

WIRE THE ENTRAPMENT PROTECTION DEVICES

Entrapment protection devices are required. Refer to page 5 for more information regarding application.

EARTH GROUND ROD

Use the proper earth ground rod for your local area. The ground wire must be a

single, whole piece of wire. Never splice two wires for the ground wire. If you should

cut the ground wire too short, break it, or destroy its integrity, replace it with a single

wire length.

1

Install the earth ground rod within 3 feet of the operator.

2

Run wire from the earth ground rod to the operator.

NOTE: If the operator is not grounded properly the range of the remote controls will

be reduced.

Check national and local

codes for proper depth

To Operator

1

TO ERASE LEARNED MONITORED PHOTOELECTRIC

SENSORS

1

Remove the photoelectric sensor wires from the terminal block.

2

Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET

OPEN and SET CLOSE LEDs will turn on (entering learn limit mode).

3

Press and release both SET OPEN and SET CLOSE buttons again to turn off the

SET OPEN and SET CLOSE LEDs (exiting learn limit mode).

NOTE: For dual gate applications repeat the steps above on the other operator.