Wiring accessories to the control board, Additional features – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 35

Advertising
background image

33

ADDITIONAL FEATURES

A

Open Input (&

common)

(3-Button Control

Station, 4 terminals

total)

Open command - opens a closed gate.

Hard open (maintained switch overrides external

safeties and resets alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate

(within line-of-sight).

B

Close Input (&

common)

(3-Button Control

Station, 4 terminals

total)

Close command - closes an open gate.

Hard close (maintained switch overrides external

safeties and resets alarm condition within line-of-sight)

C

Stop Input (& common)

(3-Button Control

Station, 4 terminals

total)

Stop command - stops a moving gate.

Hard stop (maintained switch overrides Open and Close

commands and resets alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Overrides Open and Close commands (within line-of-

sight).

D

Fire Dept Open Input

(2 terminals)

Acts as hard open.

Maintained input overrides (ignores) external safeties

(photoelectric sensor and edge), pauses Timer-to-Close

momentary input logic as single button control and

safeties remain active, re-enables Timer-to-Close.

E

Exit Loop Input

(2 terminals)

Open command - opens a closed gate.

Soft open (maintained switch does not override

external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

F

Shadow Loop Input

(2 terminals)

Loop detector connection when loop is positioned under

gate.

- Holds open gate at open limit

- Disregarded during gate motion

- Pauses Timer-to-Close at OPEN limit

G

CLOSE EYES/Interrupt

Loop Input

(2 terminals)

CLOSE EYES/Interrupt Loop detector connection when

loop is along the side of the gate.

- Holds open gate at open limit

- Stops and reverses a closing gate to open limit

- Pauses Timer-to-Close at OPEN limit
Close Direction Photoelectric Sensors, IR, or Infra-red

detector wired to CLOSE EYES Input, disregarded during

gate opening.

Pulsed Photoelectric Sensors = monitored device putting

out a pulse train when unblocked.

Photoelectric Sensors, IR, Infra-red detector, normally

open contact, contact opens fully with obstruction.

H

Close Edge

(2 terminals)

Close Direction Edge Sensor to Close Safety Input,

disregarded during gate opening

I

Open Eyes/Edge

(2 terminals)

Open Direction Photoelectric Sensors, IR, Infra-red

detector wired or Edge Sensor to Close Entrapments

Input, disregarded during gate closing,
Pulsed Photoelectric Sensors = monitored device putting

out a pulse train when unblocked.
Photoelectric Sensors, IR, Infra-red detector, edge

sensor = normally open contact, contact reverses for 2

seconds with obstruction.

J

Comm Link

(2 terminals)

Commercial Link (two wires) - connects two operators

together (primary-secondary wired connection)

K

Lock Outputs: Maglock

(2 terminals, N.C. and

COM)

Relay contact output, Normally - closed (N.C.) output

for maglocks
Relay activates prior to motor activation and during

motor run. Relay is off when motor is off.

L

Solenoid Lock &

Common

(2 terminals, N.O. and

COM)

Normally - open (N.O.) output for solenoid locks

Relay activates prior to motor activation and during

motor run. Relay is off when motor is off.

M

Accessory Power Out

Switched,

(2 terminals)

Switched ON with gate motion (stays on 5 seconds after

motion)

N

Accessory Power Out

Un-switched,

(2 terminals)

24 Vdc voltage out to power accessories, always ON

Open
Close
Stop
Com

Com

Com

Com

Interrupt
Close Edge (+)

Fire Dept

Exit

Shadow

Close Eyes

Close Edge (-)

Comm Link Data A

Comm Link Data B

Open Eyes/Edge (+)

Open Eyes/Edge (-)

Lock N.C. (Maglock)
Com

Lock N.O. (Solenoid)
Com (-)
AccPower +24 Vdc
Com (-)

AccPower +24 Vdc

3 Button

Station

Fire Dept.

Exit Loop

Shadow Loop

Close Eyes/

Interrupt Loop

Comm Link

Close Edge

Open Eyes/Edge

Mag and

Solenoid Lock

A

B

C

D

E
F
G
H
I

J

K

L

M
N

Acc. Power

(right side of control board)

WIRING ACCESSORIES TO THE CONTROL BOARD

WIRING ACCESSORIES TO THE CONTROL BOARD

Refer to the chart below and the corresponding image for a description of the control

board inputs.