CONTROL BOARD LEDS

The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist with programming, and

diagnose potential problems with the operator.
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.

CONTROL BOARD LEDS

TROUBLESHOOTING

STATUS LEDS

LIMIT SETUP LEDS

SET OPEN

LED

SET CLOSE

LED

OPERATOR MODE

EXPLANATION

BLINKING

BLINKING

NORMAL MODE

Limits are not set.

OFF

OFF

NORMAL MODE

Limits are set.

BLINKING

BLINKING

LIMIT SETTING MODE

Limits are not set.

BLINKING

ON

LIMIT SETTING MODE

Open limit is not set.

ON

BLINKING

LIMIT SETTING MODE

Close limit is not set.

ON

ON

LIMIT SETTING MODE

Limits are set.

LIMIT SETUP LEDS

GREEN XMITTER LED

DIAGNOSTIC CODES LEDS

INPUT LEDS

YELLOW NETWORK LED

GREEN XMITTER LED

XMITTER LED

EXPLANATION

OFF

No remote control activity, normal operation.

ON

Programming mode active.

ON (for 1 second)

Recognized remote control signal.

ON (for a 1/4 of a second)

Unrecognized remote control signal.

ON (8 blinks per second)

Remote controls are being erased.