Dual gates only, Wiring – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 26

Advertising
background image

24

DUAL GATES ONLY

WIRING

DUAL GATES ONLY

WIRELESS DUAL GATES

TO ACTIVATE THE WIRELESS FEATURE:

1

Choose an operator to be the network primary operator. All wireless

accessories will need to be programmed to the primary operator. NOTE:

We recommend that all accessories and board configurations are set on

the primary operator.

2

Press and release the LEARN RADIO button on the primary operator. The

green XMITTER LED will light.

3

Press and release the LEARN RADIO button again on the primary

operator. The NETWORK LED will light.

4

Press and release the OPEN test button to assign this operator as network

primary.

5

Press and release the LEARN RADIO button on the second operator. The

green XMITTER LED will light.

6

Press and release the LEARN RADIO button again on the second operator.

The NETWORK LED will light.

7

Press and release the CLOSE test button to assign this operator as network

second.

Both operators will beep and the NETWORK LEDs will turn off indicating

programming is successful.

TO DEACTIVATE THE WIRELESS FEATURE:

1

Press and release the LEARN RADIO button on either operator. The green

XMITTER LED will light.

2

Press and release the LEARN RADIO button again on the same operator.

The yellow NETWORK LED will light.

3

Press and hold the LEARN RADIO button for 5 seconds. The yellow

NETWORK LED will blink (operator will beep) then turn off indicating

successful deactivation.

Repeat the steps for the other operator.

There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use

wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications.