Adjustment, Limit and force adjustment, Limit setup leds – LiftMaster CSW24V High-Cycle Commercial DC Swing Gate Operator User Manual

Page 28

Advertising
background image

26

OP

EN limit

CLOSE limit

!

3

1

2

4

5

To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons (particularly small

children) could be SERIOUSLY INJURED or KILLED by a moving gate.

• Too much force on gate will interfere with proper operation of safety reversal

system.

• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.

• If one control (force or travel limits) is adjusted, the other control may also

need adjustment.

• After ANY adjustments are made, the safety reversal system MUST be tested.

Gate MUST reverse on contact with a rigid object.

• Keep clear of moving arm while setting limits.

LIMIT AND FORCE ADJUSTMENT

LIMIT AND FORCE ADJUSTMENT

ADJUSTMENT

INTRODUCTION

Your operator is designed with electronic controls to make travel limit and force

adjustments easy. The adjustments allow you to program where the gate will stop in

the open and close position. The electronic controls sense the amount of force

required to open and close the gate. The force is adjusted automatically when you

program the limits but should be fine tuned using the REVERSAL FORCE dial on the

control board (refer to Fine Tune the Force section) to compensate for environmental

changes. The limit setup LEDs (located next to the SET OPEN and SET CLOSE buttons)

indicate the status of the limits, refer to the table to the right.
The limits can be set using the control board (below) or a remote control (refer to

Limit Setup with a Remote Control in the Additional Features section). Setting the

limits with a remote control requires a 3-button remote control programmed to

OPEN, CLOSE, and STOP.
NOTE: The Test Buttons on the control board will not work until the limits have been

set.

INITIAL LIMITS AND FORCE ADJUSTMENT

For dual gate applications the limits will have to be set for each

operator. The gate MUST be attached to the operator before setting the

limits and force.

1

Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter

limit setting mode.

2

Press and hold one of the MOVE GATE buttons to move the gate to the open or

close limit.

3

Press and release the SET CLOSE or SET OPEN button depending on which limit is

being set.

4

Press and hold one of the MOVE GATE button to move the gate to the other

limit.

5

Press and release the SET CLOSE or SET OPEN button depending on which limit is

being set.

6

Cycle the gate open and close. This automatically sets the force.

When limits are set properly the operator will automatically exit limit setting mode.

6

LIMIT SETUP LEDS

SET OPEN

LED

SET CLOSE

LED

OPERATOR MODE

EXPLANATION

BLINKING

BLINKING

NORMAL MODE

Limits are not set.

OFF

OFF

NORMAL MODE

Limits are set.

BLINKING

BLINKING

LIMIT SETTING MODE

Limits are not set.

BLINKING

ON

LIMIT SETTING MODE

Open limit is not set.

ON

BLINKING

LIMIT SETTING MODE

Close limit is not set.

ON

ON

LIMIT SETTING MODE

Limits are set.

Advertising