Recording Rules ‐ USB 3.0 (Voyager/Advisor T3 only)
306
USB Protocol Suite User Manual
RD Error
DP Length Error
Term On
Term Off
BCNT
CRC32
CRC16
CRC5LCW
CRC5LC
Framing Error Triggers
SLC
SDP
SHP
END
Low Power States
U1
U2
U3
Note:
Data Pattern Matching ‐ For USB 3.0, only the first 32 Byte positions can be matched for
triggering. It is not a floating window as it is for USB 2.0 Data Pattern Match.
Note:
Warm Reset Trigger ‐ The position of this trigger in the file can be deceptive due to the
imbalance of traffic between the transmit and receive traffic. It can be helpful to hide upstream
or downstream traffic to see where it occurred with respect to traffic on the one stream.