Installation – Lincoln Electric IM10114 TANDEM CRUISER User Manual

Page 26

Advertising
background image

A-19

INSTALLATION

TANDEM CRUISER™

A-19

WELD CABLE SIZES

See Table A.1 for copper cable sizes recommended
for different currents and duty cycles. Lengths stipulat-
ed are the distance from the welder to work and back
to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable drop.

TABLE A.1

** Tabled values are for operation at ambient tempera-

tures of 40°C and below. Applications above 40°C
may require cables larger than recommended, or
cables rated higher than 75°C.

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK
CABLES

Amperes

Percent

Duty
Cycle

0 to 50 Ft.

50 to 100 Ft.

100 to 150 Ft.

150 to 200 Ft.

200 to 250 Ft.

600
600
600
650
650
700

60
80

100

60
80

100

3/0

2-1/0
2-1/0

3/0

2-1/0
2-2/0

3/0

2-1/0
2-1/0

3/0

2-1/0
2-2/0

3/0

2-1/0
2-1/0

4/0

2-1/0
2-3/0

4/0

2-2/0
2-2/0
2-2/0
2-2/0
2-3/0

2-3/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0

800
800

1000

80

100

80

3-1/0
2-3/0
2-4/0

3-1/0
2-3/0
2-4/0

3-1/0
2-3/0
2-4/0

2-3/0
2-3/0
2-4/0

2-4/0
2-4/0
4-2/0

1000
1200
1200
1500
1500

100

80

100

80

100

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

3-3/0
3-4/0
4-4/0
4-4/0
5-4/0

Advertising