Operation, Parameter, Definition – Lincoln Electric IM10114 TANDEM CRUISER User Manual

Page 47

Advertising
background image

B-11

OPERATION

B-11

SET-UP FEATURES MENU

The Setup Menu gives access to the set-up configuration. Stored in the set-up configuration are user parameters
that generally need to be set only at installation. The parameters are grouped as follows:

To access the set-up menu, press the right and left buttons of the MSP4 panel simultaneously. Note that the set-
up menu cannot be accessed if the system is welding, or if there is a fault (The status LED is not solid green).

Change the value of the blinking parameter by rotating the SET knob.

To exit the set-up menu at any time, press the right and left buttons of the MSP4 panel simultaneously. Alternately,
1 minute of inactivity will also exit the set-up menu.

TANDEM CRUISER™

PARAMETER

P.1 through P.99

P.101 through P.199
P.501
through P.599

DEFINITION

Unsecured Parameters (always adjustable)

Diagnostic Parameters (always read only)

Secured Parameters (only accessible with Weld Manager)

PARAMETER

DEFINITION

P.0

Press the left button to exit the set-up menu.

P.1

Wire Feed Speed Units
This option selects which units to use for displaying wire feed speed.
English = inches/minute wire feed speed units (default).
Metric = meters/minute wire feed speed units.

P.2

Arc Display Mode
This option selects what value will be shown on the upper left display while
welding.
Amps = The left display shows Amperage while welding (default).
WFS = The left display shows Wire Feed Speed while welding.

P.3

Display Options
This setup parameter was previously named "Display Energy"

If the previous software revision had this parameter set to display energy, that
selection will remain.

This option selects the information displayed on the alphanumeric displays
while welding. Not all P.3 selections will be available on all machines. In order
for each selection to be included in the list, the power source must support
that feature. A software update of the power source may be needed to include
the features.

Standard Display = The lower displays will continue to show preset informa-
tion during and after a weld (default).
Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.

Advertising