B-14

OPERATION

B-14

TANDEM CRUISER™

P.100

View Diagnostics
Diagnostics are only used for servicing or troubleshooting the Power Wave
system. Select "Yes" to access the diagnostic options in the menu. Additional
parameters will now appear in the setup menu (P.101, P.102, etc).

P.101

Event Logs
Used for viewing all the system event logs. Press the Right Button to enter the
option. Rotate Control Knob to select the desired event log to read. Press the
Right Button again to enter the selected log. Rotating the Control Knob will
scroll through the event log, displaying the log index number, event code and
some other data. Press the Left Button to back out to select another log.
Press the Left Button again to exit this option.

P.102

Fatal Logs
Used for viewing all the system fatal logs. Press the Right Button to enter the
option. Rotate Control Knob to select the desired fatal log to read. Press the
Right Button again to enter that log. Rotating the Control Knob will scroll
through the log, displaying the log index number and fatal code. Press the Left
Button to back out to select another log. Press the Left Button again to exit this
option.

P.103

Software Version
Used for viewing the software versions for each board in the system. Press
the Right Button to enter the option. Rotate Control Knob to select the desired
board to read. Press the Right Button again to read the firmware version.
Press the Left Button to back out to select another board. Rotate the Control
Knob to select another board, or press the Left Button to exit this option.

P.104

Hardware Version
Used for viewing the hardware version for each board in the system. Press
the Right Button to enter the option. Rotate Control Knob to select the desired
board to read. Press the Right Button again to read the hardware version.
Press the Left Button to back out to select another board. Press the Left
Button again to exit this option.

PARAMETER

DEFINITION

P.80

Sense from Studs.
Use this option for diagnostic purposes only. When power is cycled, this
option is automatically reset to False.
False = Voltage sensing is automatically determined by the selected weld
mode and other machine settings (default).
True = Voltage sensing is forced to "studs".

P.99

Show Test Modes
Most power sources contain weld modes used for calibration and test pur-
poses. By default, the machine does not include test weld modes in the list of
weld modes that are available to the operator. To manually select a test weld
mode, set this option to "Yes". When the power source is turned off and back
on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and
cannot be used for welding.