Wiegmann WAX-MSSN4 Series User Manual
Page 11

S N 4 S E R I E S E N C L O S U R E S
N E M A 4 F L A N G E D S I N G L E D O O R D I S C O N N E C T
F11
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
2.00
3.00
1.25
3.00
0.63
H
1.25
0.63
0.44
W-3.13
H-1.63
X
X
W
DOOR STIFFENER
IF H = 42.00" OR
MORE
D
D-0.28
Y
Y
0.88
0.88
B
1.75
2.62
MOUNTING FEET
PANEL
(Order
Separately)
STIFFENER
SEE Page F27
OMIT TWO MIDDLE
STUDS IF H = LESS
THAN 31.00"
OMIT TWO MIDDLE STUDS
IF W = LESS THAN 32.00"
SECTION Y-Y
0.19
D
0.88
0.63
1.31
1.09
12 GA.
0.75
2.75
14 GA.
2.50
1.25 TYP
3/8 - 16 COLLAR
STUD
PANEL
(ORDER SEPARATELY)
BODY
STIFFENER
MOUNTING
FEET
DOOR
STIFFENER
CONTINUOUS
HINGE
GASKET
SECTION X-X
E
F
W
2.75
1.59
1.50
Ø0.44
3.00
TYP
Space Occupied by Disconnect
E = 8.63 when Depth = 8.00
E = 11.62 when Depth = 12.00
WB = Wiring Space
See pages F16-F22 for various brands of disconnects
for “F”, “G”, & “WB” dimensions.
Disconnects will occupy space on panel shown by dimensions
“E”, “F”, & “G”. Wiring space “WB” is available when disconnect
is installed in the enclosure.
Refer to National Electrical Code article 430-10(b) for wiring
space required for line side conductors to be connected to disconnect.
Verify your application to determine if wiring space is adequate.
TOP HOLE IN
R.H. FLANGE
Notes:
1. Large print pocket (8" x 10") is
provided in each enclosure.
2. Panels are made from 12 Ga. steel.
5. See page F27 for Stiffener Location.
3. Panels have flanges along all sides
when either dimension exceeds 17".
4. The number of door clamps is
dependent on size of enclosure.
Clamps are furnished along three
sides of door.
1.50
A
1.50
H-6.00
G
THIS SPACE IS OCCUPIED
BY DISCONNECT SWITCH
AND FUSE CLIP (IF USED)
OR CIRCUIT BREAKER.