Wiegmann WAX-MSSN4 Series User Manual

Page 58

Advertising
background image

F58

www.hubbell-wiegmann.com

Data Subject To Change Without Notice

SWITCH

AMP

FUSE

FUSE

DISCONNECT

DISCONNECT

TWO DOOR

FREESTANDING & MODULAR

RATING

CLIP

CLASS

HEIGHT X

WIDTH Y

FLOOR-MOUNT

MCS603R

3 0 A

N o f u s e

5 . 5 2

6 . 1 3

MCS603R

3 0 A

3 0 A - 2 5 0 V

H , K , R

8 . 1 1

6 . 1 3

MCS603R

3 0 A

3 0 A - 6 0 0 V

H , K , R

1 0 . 1 1

6 . 1 3

MCS603R

3 0 A

3 0 A - 6 0 0 V

J

8 . 4 8

6 . 1 3

MCS606R

6 0 A

N o f u s e

5 . 5 2

6 . 1 3

MCS606R

6 0 A

6 0 A - 2 5 0 V

H , K , R

7 . 8 6

6 . 1 3

MCS606R

6 0 A

6 0 A - 6 0 0 V

H , K , R

1 0 . 3 8

6 . 1 3

F o r e n c l o s u r e s

MCS606R

6 0 A

6 0 A - 6 0 0 V

J

8 . 3 6

6 . 1 3

t h a t a c c e p t

MCS610R

1 0 0 A

N o f u s e

7 . 5 9

7 . 3 8

t h e s e d e v i c e s ,

MCS610R

1 0 0 A

1 0 0 A - 2 5 0 V

H , K , R

1 1 . 8 5

7 . 3 8

s e e p a g e s

MCS610R

1 0 0 A

1 0 0 A - 6 0 0 V

H , K , R

1 3 . 8 5

7 . 3 8

F 2 8 - F 2 9 &

MCS610R

1 0 0 A

1 0 0 A - 6 0 0 V

J

1 0 . 6 0

7 . 3 8

F 4 5 - F 4 6

MCS620R

2 0 0 A

N o f u s e

9 . 0 0

9 . 1 7

MCS620R

2 0 0 A

2 0 0 A - 2 5 0 V

H , K , R

1 4 . 7 0

9 . 1 7

MCS620R

2 0 0 A

2 0 0 A - 6 0 0 V

H , K , R

1 7 . 2 0

9 . 1 7

MCS620R

2 0 0 A

2 0 0 A - 6 0 0 V

J

1 3 . 3 2

9 . 1 7

S I E M E N S I T E M A X - F L E X

D I S C O N N E C T S W I T C H E S F O R M A X - F L E X

O P E R AT O R S

2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosures, that are 24.00-inches deep, require a 48-inch Max-Flex

cable (minimum cable length).

Mechanisms and circuit breakers listed above will fit any 2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosure.

Catalog numbers are for complete mechanisms which include flange-mounted handle, flexible operating cable, and circuit breaker operator. The last 3 digits
indicate cable length in inches.

24" deep enclosures require longer operating cables. Order components separately.

* Circuit breakers size includes required base mounting block.

COMPLETE OPERATOR CIRCUIT

MAXIMUM

CIRCUIT BREAKER

CIRCUIT BREAKER

CIRCUIT BREAKER TYPE

MECHANISM

FRAME SIZE

AMP RATING

HEIGHT X

WIDTH Y

FHOE036

E D

1 2 5 A

6 . 3 4

3 . 0 0

E D 2 . E D 4 . E D 6 . H E D 4 . H E D 6

FHOE036

C E D

1 2 5 A

9 . 5 8

3 . 0 0

C E D 6

FHOF036

F D

2 5 0 A

9 . 5 0

4 . 5 0

F X D 6 - A , F D 6 - A , H F D 6 , F X D 6 - E T J , H H F D 6 , H H F X D 6

FHOF036

C F D

2 5 0 A

1 4 . 2 5

4 . 5 0

C F D 6 , C F D 6 - E T I

FHOJ036

J D

4 0 0 A

1 1 . 0 0

7 . 5 0

J X D 2 , L X D 6 , J D 6 , H J D 6 , H H J D 6 , H H J X D 6 , J X D 6 - E T I

FHOJ036

C J D

4 0 0 A

1 7 . 8 6

7 . 5 0

C J D 6 , C J D 6 - E T I

FHOJ036

L D

6 0 0 A

1 1 . 0 0

7 . 5 0

L X D 6 , L D 6 , H L D 6 , H H L D 6 , H H L D X 6 , L X D 6 - E T I

FHOJ036

C L D

6 0 0 A

1 7 . 8 6

7 . 5 0

C L D 6 , C L D 6 - E T I

FHOLM036

L M D

8 0 0 A

1 6 . 0 0

9 . 0 0

L M D 6 , L M X D 6 , H L M D 6 , H L M X D 6 , L M X D 6 - E T I

FHON048

M D

8 0 0 A

2 4 . 0 0

9 . 0 0

MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI

FHON048

N D

1 2 0 0 A

2 4 . 0 0

9 . 0 0

N D 6 , N X D 6 , H N D 6 , H N X D 6 , C N D 6

FHON048*

P D

1 6 0 0 A

2 4 . 5 0

1 3 . 6 3

P D 6 , P X D 6 , H P D 6 , H P X D 6 , C P D 6

FHON048*

R D

2 0 0 0 A

2 4 . 5 0

1 3 . 6 3

R D 6 , R X D 6 , H R D 6 , H R X D 6

S I E M E N S I T E M A X - F L E X

C I R C U I T B R E A K E R S F O R M A X - F L E X

O P E R AT O R S

†For Two Door Floor-Mount NEMA 12

“E” = 7.88 when “H” = 60.12

(Pages F28-F29 & F45-F46)

“E” = 13.38 when “H” = 72.12

(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)

For Heavy Duty Freestanding

“E” = 11.88 when “H” = 72.12

and Modular Enclosures

“E” = 17.38 when “H” = 84.12

(Pages F32 - F49)

“E” = 20.38 when “H” = 90.12

(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)

Space Occupied by Circuit Breaker

• The Siemens ITE Max-Flex

cable system allows the disconnect to be positioned independent from the flange-mounted handle mechanism.

• Refer to National Electrical Code

®

article 430-10(b) for wiring space “WB” required for line side conductors.

• Refer to Siemens ITE Max-Flex

installation instructions for limits on disconnect location when using 36" or 48" Max-Flex

cables.

• Space occupied by disconnect is determined by overall height “X”, width “Y”, wire bend space “WB” and location “G” as selected from right to left.

F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S
D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N

F o r e n c l o s u r e s t h a t a c c e p t

t h e s e d e v i c e s ,

( S e e p a g e s F 3 2 - F 4 9 )