Wiegmann WAX-MSSN4 Series User Manual
Page 58

F58
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
SWITCH
AMP
FUSE
FUSE
DISCONNECT
DISCONNECT
TWO DOOR
FREESTANDING & MODULAR
RATING
CLIP
CLASS
HEIGHT X
WIDTH Y
FLOOR-MOUNT
MCS603R
3 0 A
N o f u s e
—
5 . 5 2
6 . 1 3
MCS603R
3 0 A
3 0 A - 2 5 0 V
H , K , R
8 . 1 1
6 . 1 3
MCS603R
3 0 A
3 0 A - 6 0 0 V
H , K , R
1 0 . 1 1
6 . 1 3
MCS603R
3 0 A
3 0 A - 6 0 0 V
J
8 . 4 8
6 . 1 3
MCS606R
6 0 A
N o f u s e
—
5 . 5 2
6 . 1 3
MCS606R
6 0 A
6 0 A - 2 5 0 V
H , K , R
7 . 8 6
6 . 1 3
MCS606R
6 0 A
6 0 A - 6 0 0 V
H , K , R
1 0 . 3 8
6 . 1 3
F o r e n c l o s u r e s
MCS606R
6 0 A
6 0 A - 6 0 0 V
J
8 . 3 6
6 . 1 3
t h a t a c c e p t
MCS610R
1 0 0 A
N o f u s e
—
7 . 5 9
7 . 3 8
t h e s e d e v i c e s ,
MCS610R
1 0 0 A
1 0 0 A - 2 5 0 V
H , K , R
1 1 . 8 5
7 . 3 8
s e e p a g e s
MCS610R
1 0 0 A
1 0 0 A - 6 0 0 V
H , K , R
1 3 . 8 5
7 . 3 8
F 2 8 - F 2 9 &
MCS610R
1 0 0 A
1 0 0 A - 6 0 0 V
J
1 0 . 6 0
7 . 3 8
F 4 5 - F 4 6
MCS620R
2 0 0 A
N o f u s e
—
9 . 0 0
9 . 1 7
MCS620R
2 0 0 A
2 0 0 A - 2 5 0 V
H , K , R
1 4 . 7 0
9 . 1 7
MCS620R
2 0 0 A
2 0 0 A - 6 0 0 V
H , K , R
1 7 . 2 0
9 . 1 7
MCS620R
2 0 0 A
2 0 0 A - 6 0 0 V
J
1 3 . 3 2
9 . 1 7
S I E M E N S I T E M A X - F L E X
™
D I S C O N N E C T S W I T C H E S F O R M A X - F L E X
™
O P E R AT O R S
†
2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosures, that are 24.00-inches deep, require a 48-inch Max-Flex
™
cable (minimum cable length).
Mechanisms and circuit breakers listed above will fit any 2 Door Floor-Mount NEMA 12, Heavy Duty Freestanding and Modular Enclosure.
Catalog numbers are for complete mechanisms which include flange-mounted handle, flexible operating cable, and circuit breaker operator. The last 3 digits
indicate cable length in inches.
24" deep enclosures require longer operating cables. Order components separately.
* Circuit breakers size includes required base mounting block.
COMPLETE OPERATOR CIRCUIT
MAXIMUM
CIRCUIT BREAKER
CIRCUIT BREAKER
CIRCUIT BREAKER TYPE
MECHANISM
FRAME SIZE
AMP RATING
HEIGHT X
WIDTH Y
FHOE036
E D
1 2 5 A
6 . 3 4
3 . 0 0
E D 2 . E D 4 . E D 6 . H E D 4 . H E D 6
FHOE036
C E D
1 2 5 A
9 . 5 8
3 . 0 0
C E D 6
FHOF036
F D
2 5 0 A
9 . 5 0
4 . 5 0
F X D 6 - A , F D 6 - A , H F D 6 , F X D 6 - E T J , H H F D 6 , H H F X D 6
FHOF036
C F D
2 5 0 A
1 4 . 2 5
4 . 5 0
C F D 6 , C F D 6 - E T I
FHOJ036
J D
4 0 0 A
1 1 . 0 0
7 . 5 0
J X D 2 , L X D 6 , J D 6 , H J D 6 , H H J D 6 , H H J X D 6 , J X D 6 - E T I
FHOJ036
C J D
4 0 0 A
1 7 . 8 6
7 . 5 0
C J D 6 , C J D 6 - E T I
FHOJ036
L D
6 0 0 A
1 1 . 0 0
7 . 5 0
L X D 6 , L D 6 , H L D 6 , H H L D 6 , H H L D X 6 , L X D 6 - E T I
FHOJ036
C L D
6 0 0 A
1 7 . 8 6
7 . 5 0
C L D 6 , C L D 6 - E T I
FHOLM036
L M D
8 0 0 A
1 6 . 0 0
9 . 0 0
L M D 6 , L M X D 6 , H L M D 6 , H L M X D 6 , L M X D 6 - E T I
FHON048
M D
8 0 0 A
2 4 . 0 0
9 . 0 0
MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI
FHON048
N D
1 2 0 0 A
2 4 . 0 0
9 . 0 0
N D 6 , N X D 6 , H N D 6 , H N X D 6 , C N D 6
FHON048*
P D
1 6 0 0 A
2 4 . 5 0
1 3 . 6 3
P D 6 , P X D 6 , H P D 6 , H P X D 6 , C P D 6
FHON048*
R D
2 0 0 0 A
2 4 . 5 0
1 3 . 6 3
R D 6 , R X D 6 , H R D 6 , H R X D 6
S I E M E N S I T E M A X - F L E X
™
C I R C U I T B R E A K E R S F O R M A X - F L E X
™
O P E R AT O R S
†
†For Two Door Floor-Mount NEMA 12
“E” = 7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46)
“E” = 13.38 when “H” = 72.12
(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)
For Heavy Duty Freestanding
“E” = 11.88 when “H” = 72.12
and Modular Enclosures
“E” = 17.38 when “H” = 84.12
(Pages F32 - F49)
“E” = 20.38 when “H” = 90.12
(Deduct 1.45 inches from "E" for FHON048 operator mechanism for MD, ND, PD, RD circuit breakers.)
Space Occupied by Circuit Breaker
• The Siemens ITE Max-Flex
™
cable system allows the disconnect to be positioned independent from the flange-mounted handle mechanism.
• Refer to National Electrical Code
®
article 430-10(b) for wiring space “WB” required for line side conductors.
• Refer to Siemens ITE Max-Flex
™
installation instructions for limits on disconnect location when using 36" or 48" Max-Flex
™
cables.
• Space occupied by disconnect is determined by overall height “X”, width “Y”, wire bend space “WB” and location “G” as selected from right to left.
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S
D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N
F o r e n c l o s u r e s t h a t a c c e p t
t h e s e d e v i c e s ,
( S e e p a g e s F 3 2 - F 4 9 )