Wiegmann WAX-MSSN4 Series User Manual

Page 21

Advertising
background image

A B N 1 2 , S D N 1 2 , S D N 1 2 P L , N 4 1 2 C D ,

N 4 1 2 C S T D , N 4 1 2 C S S S T D , S N 4 & S S N 4 X S E R I E S E N C L O S U R E S

D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N

F21

www.hubbell-wiegmann.com

Data Subject To Change Without Notice

SWITCH

AMP

FUSE

FUSE

DISCONNECT

DISCONNECT

ABN12, SDN12, SDN12PL, N412CD,

SN4 & SSN4X

RATING

CLIP

CLASS

HEIGHT X

WIDTH Y

N412CSTD, N412CSSSTD, SN4 & SSN4X

WALL-MOUNTS

TCN-30C

3 0 A

N o f u s e

5 . 9 0

6 . 2 0

TCF-30C

3 0 A

3 0 A - 2 5 0 V

H , K , R

7 . 5 0

6 . 2 0

TCF-33C

3 0 A

3 0 A - 6 0 0 V

H , K , R

1 0 . 1 5

6 . 2 0

TCF-33C

3 0 A

6 0 A - 2 5 0 V

H , K , R

8 . 1 5

6 . 2 0

TCF-33C

3 0 A

3 0 A - 6 0 0 V

J

7 . 5 0

6 . 2 0

TDN-60C

6 0 A

N o f u s e

5 . 9 0

6 . 2 0

TDF-60C

6 0 A

3 0 A - 6 0 0 V

H , K , R

1 0 . 1 5

6 . 2 0

TDF-60C

6 0 A

6 0 A - 2 5 0 V

H , K , R

8 . 1 5

6 . 2 0

TDF-63C

6 0 A

6 0 A - 6 0 0 V

H , K , R

1 0 . 6 5

6 . 2 0

TDF-63C

6 0 A

6 0 A - 6 0 0 V

J

7 . 5 0

6 . 2 0

TEN-10C

1 0 0 A

N o f u s e

5 . 9 0

6 . 2 0

TEF-10C

1 0 0 A

1 0 0 A - 2 5 0 V

H , K , R

1 0 . 3 5

6 . 2 0

TEF-10C

1 0 0 A

1 0 0 A - 6 0 0 V

H , K , R

1 0 . 3 5

6 . 2 0

TEF-10C

1 0 0 A

1 0 0 A - 6 0 0 V

J

1 0 . 3 5

6 . 2 0

SCHNEIDER SQUARE D

®

CLASS 9422 DISCONNECT SWITCHES USED WITH CABLE MECHANISM 9422-CFT30 & 9422A-1 HANDLE MECHANISM

CABLE TYPE

AMP

FRAME

CIRCUIT BREAKER

CIRCUIT BREAKER

ABN12, SDN12, SDN12PL, N412CD,

SN4 & SSN4X

SWITCH

RATING

TYPE

HEIGHT X

WIDTH Y

N412CSTD, N412CSSSTD, SN4 & SSN4X

WALL-MOUNTS

9422 CGJ30

7 5 A

G J L

4 . 7 5

3 . 5 0

9422 CGJ300

1 0 0 A

G J L

4 . 7 5

3 . 5 0

9422 CGJ30

1 0 0 A

FA L , F H L

6 . 0 0

4 . 5 0

9422 CGJ30

2 5 0 A

K A L , K H L

8 . 0 0

4 . 5 0

9422 CGJ30

4 0 0 A

L A L , L H L , Q 4 L

1 1 . 0 0

6 . 0 0

SCHNEIDER SQUARE D

®

C L A S S 9 4 2 2 C A B L E M E C H A N I S M F O R C I R C U I T B R E A K E R S

Use switches listed above with appropriate cable mechanism and 9422-A1 handle mechanism.

Use cable mechanism with appropriate circuit breaker and 9422-A1 handle mechanism. Cable operators are available in 3-foot, 5-foot, and 10-foot lengths.
Numbers shown (30) are for 3-foot cables.

F o r e n c l o s u r e s t h a t

a c c e p t t h e s e d e v i c e s ,

s e e p a g e s F 2 - F 9 .

F o r e n c l o s u r e s t h a t

a c c e p t t h e s e d e v i c e s ,

s e e p a g e s F 1 0 - F 1 3 .

F o r e n c l o s u r e s t h a t

a c c e p t t h e s e d e v i c e s ,

s e e p a g e s F 2 - F 9 .

F o r e n c l o s u r e s t h a t

a c c e p t t h e s e d e v i c e s ,

s e e p a g e s F 1 0 - F 1 3 .

Mechanisms and circuit breakers listed above will fit any disconnect wall-mounts
on pages F10-F13, or SN4 wall-mounts on pages F2-F9 except as noted.
The last 3 digits of operator mechanism number indicates cable length in inches.
Also 48" cables are available for ED, FD, JD/LD operators, and 60" cables for
MD/ND, PD/RD operators.
For Type 4 applications order handle, cable and circuit breaker separately.
* This operator mechanism can only be installed in catalog number

SDN12603812A (see page F3) which has the appropriate flange cutout.

Space Occupied by Disconnect

• The Siemens ITE Max-Flex

cable system allows the disconnect to be posi-

tioned independent from the flange-mounted handle mechanism.

• Refer to National Electrical Code

®

article 430-10(b) for wiring space “WB”

required for line side conductors.

• Refer to Siemens ITE Max-Flex

installation instructions for limits on discon-

nect location when 36-inch or 48-inch Max-Flex

cables.

• Space occupied by disconnect is determined by overall height “X”, width

“Y”, wire bend space “WB” and location “G” as selected from right to left.

COMPLETE OPERATOR CIRCUIT BREAKER

MAXIMUM

CIRCUIT BREAKER CIRCUIT BREAKER

CIRCUIT BREAKER TYPE

MECHANISM

FRAME

AMP RATING HEIGHT X

WIDTH Y

FHOE036

E D

1 2 5 A

6 . 3 4

3 . 0 0

E D 2 . E D 4 . E D 6 . H E D 4 . H E D 6

FHOE036

C E D

1 2 5 A

9 . 5 8

3 . 0 0

C E D 6

FHOF036

F D

2 5 0 A

9 . 5 0

4 . 5 0

F X D 6 - A , F D 6 - A , H F D 6 , F X D 6 - E T J , H H F D 6 , H H F X D 6

FHOJ036

C F D

2 5 0 A

1 4 . 2 5

4 . 5 0

C F D 6 , C F D 6 - E T I

FHOJ036

J D

4 0 0 A

1 1 . 0 0

7 . 5 0

J X D 2 , J X D 6 , J D 6 , H J D 6 , H H J D 6 , H H J X D 6 , J X D 6 - E T I

FHOJ036

C J D

4 0 0 A

1 7 . 8 6

7 . 5 0

C J D 6 , C J D 6 - E T I

FHOJ036

L D

6 0 0 A

1 1 . 0 0

7 . 5 0

L X D 6 , L D 6 , H L D 6 , H H L D 6 , H H L D X 6 , L X D 6 - E T I

FHOJ036

C L D

6 0 0 A

1 7 . 8 6

7 . 5 0

C L D 6 , C L D 6 - E T I

FHOLM036

L M D

8 0 0 A

1 6 . 0 0

9 . 0 0

L M D 6 , L M X D 6 , H L M D 6 , H L M X D 6 , L M X D 6 - E T I

FHON048*

M D

8 0 0 A

2 4 . 0 0

9 . 0 0

MD2, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI

FHON048*

N D

1 2 0 0 A

2 4 . 0 0

9 . 0 0

N D 6 , N X D 6 , H N D 6 , H N X D 6 , C N D 6

S I E M E N S I T E C I R C U I T B R E A K E R S F O R M A X - F L E X

O P E R AT O R S

Space Occupied by Disconnect Switch or Circuit Breaker

• Schneider Square D

®

cable mechanisms allows disconnect devices to be

positioned independent from the flange-mounted handle mechanism.

• Refer to National Electrical Code

®

article 430-10(b) for wiring space "WB"

required for line side conductors.

• Choose cable mechanism length based on placement of disconnect in

enclosure. See Schneider Square D

®

Instruction Bulletin for minimum bend

radius for cable.

• Space occupied by disconnect is determined by overall height “X”, width

“Y”, wire bend space “WB” and location “G” as selected from right to left.