F55

www.hubbell-wiegmann.com

Data Subject To Change Without Notice

SM101PR

F B Tr i - P a c

8 . 0 0

5 . 3 8

0 . 8 1

6 . 5 0

1 2 . 5 0

1 0 . 5 0

1 6 . 5 0

1 9 . 5 0

SM150R

F F r a m e : E H D , F D B , F D , H F D , F D C

8 . 0 0

5 . 3 8

0 . 8 1

6 . 5 0

1 2 . 5 0

1 0 . 5 0

1 6 . 5 0

1 9 . 5 0

SM250JR

J F r a m e : J D B , J D , H J D , J D C

8 . 5 0

7 . 5 0

0 . 8 1

1 0 . 0 0

8 . 0 0

1 4 . 0 0

1 7 . 0 0

SM400KR

K F r a m e : D K , K D B , K D , H K D

9 . 0 6

7 . 5 0

0 . 8 1

9 . 6 2

7 . 6 2

1 3 . 6 2

1 6 . 6 2

SM400PR

L A Tr i - P a c

1 4 . 4 4

9 . 7 5

0 . 8 1

9 . 7 5

7 . 7 5

1 3 . 7 5

1 6 . 7 5

SM600R

L F r a m e : L D , H L D , L D C

8 . 8 1

7 . 6 2

0 . 8 1

1 2 . 8 8

1 5 . 8 8

SM800R

M F r a m e : M D , M D S , H M D

1 0 . 6 8

9 . 7 5

0 . 8 1

1 0 . 1 6

1 3 . 1 6

SM800PR

N B Tr i - P a c

1 6 . 8 1

9 . 7 5

0 . 8 1

1 0 . 1 6

1 3 . 1 6

HANDLE

USE WITH

SPACE OCCUPIED

WHEN

WHEN

WHEN

WHEN

WHEN

MECHANISM

CIRCUIT BREAKER

F

G

K

H=60.12

H=72.12

H=72.12

H=84.12

H=90.12

WB

WB

WB

WB

WB

E AT O N C U T L E R - H A M M E R T Y P E S M S A F E T Y H A N D L E M E C H A N I S M S

WIRE BEND SPACE “WB” ABOVE DISCONNECT

TWO DOOR FLOOR-MOUNT

FREESTANDING & MODULAR

(PAGES F28-F29 & F45-F46)

(PAGES F32-F49)

COMPLETE OPERATOR

AMP

FRAME

BREAKER

BREAKER

MECHANISM

RATING

TYPE

HEIGHT

WIDTH

F1S03

2 2 5 A

F F r a m e : E H D , F D B , F D , H F D

6 . 0 0

4 . 1 2

F1S03

1 5 0 A

F F r a m e : H M C P

6 . 0 0

4 . 1 2

F2S03

2 5 0 A

J F r a m e : J D B , J D , H J D , J D C

1 0 . 0 0

4 . 1 2

F2S03

2 5 0 A

J F r a m e : H M C P

1 0 . 0 0

4 . 1 2

F3S03

4 0 0 A

K F r a m e : D K , K D B , K D , H K D

1 0 . 1 2

5 . 5 0

F3S03

4 0 0 A

K F r a m e : H M C P

1 2 . 4 5

5 . 5 0

F4S04

6 0 0 A

L F r a m e : L D , H L D , L D C

1 0 . 7 5

8 . 2 5

F4S04

6 0 0 A

L F r a m e : H M C P

1 2 . 5 0

8 . 2 5

F7S04

8 0 0 A

M F r a m e : M D , M D S

1 6 . 0 0

8 . 2 5

F5S04

1 2 0 0 A

N F r a m e : N D , H N D , N D C

1 6 . 0 0

8 . 2 5

F6S04

2 5 0 0 A

R F r a m e : R D , C R D , R D C

1 6 . 0 0

1 5 . 5 0

EATON CUTLER-HAMMER FLEX SHAFT

OPERATOR MECHANISMS

• Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism.

• The last digit of the catalog number denotes the length of shaft (F1S03 = 3-foot shaft). The F, J, K frame Flex Shafts

are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths.

Space Occupied by Disconnect

• The Flex Shaft

system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism.

• Refer to National Electrical Code

®

article 430-10(b) for wiring space "WB" required for line side conductors.

• Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4-inch min. bending

radius for the Flex Shaft.

• Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "WB" and location "G"

as selected from right to left.

† For Two Door Floor-Mount NEMA 12

“E” =

7.31 when “H” = 60.12 for up to type SM200

(Pages F28-F29 & F45-F46)

“E” = 12.81 when “H” = 72.12 for up to type SM200

“E” = 6.88 when “H” = 60.12 for type SM200 and larger
“E” = 12.38 when “H” = 72.12 for type SM200 and larger

For Heavy Duty Freestanding

“E” = 11.31 when “H” = 72.12 for up to type SM200

and Modular Enclosures

“E” = 16.81 when “H” = 84.12 for up to type SM200

(Pages F32 - F49)

“E” = 19.81 when “H” = 90.12 for up to type SM200
“E” = 10.88 when “H” = 72.12 for type SM200 and larger
“E” = 16.38 when “H” = 84.12 for type SM200 and larger
“E” = 19.38 when “H” = 90.12 for type SM200 and larger

F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S