Page 55

F55
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
SM101PR
F B Tr i - P a c
8 . 0 0
5 . 3 8
0 . 8 1
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
SM150R
F F r a m e : E H D , F D B , F D , H F D , F D C
8 . 0 0
5 . 3 8
0 . 8 1
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
SM250JR
J F r a m e : J D B , J D , H J D , J D C
8 . 5 0
7 . 5 0
0 . 8 1
—
1 0 . 0 0
8 . 0 0
1 4 . 0 0
1 7 . 0 0
SM400KR
K F r a m e : D K , K D B , K D , H K D
9 . 0 6
7 . 5 0
0 . 8 1
—
9 . 6 2
7 . 6 2
1 3 . 6 2
1 6 . 6 2
SM400PR
L A Tr i - P a c
1 4 . 4 4
9 . 7 5
0 . 8 1
—
9 . 7 5
7 . 7 5
1 3 . 7 5
1 6 . 7 5
SM600R
L F r a m e : L D , H L D , L D C
8 . 8 1
7 . 6 2
0 . 8 1
—
—
—
1 2 . 8 8
1 5 . 8 8
SM800R
M F r a m e : M D , M D S , H M D
1 0 . 6 8
9 . 7 5
0 . 8 1
—
—
—
1 0 . 1 6
1 3 . 1 6
SM800PR
N B Tr i - P a c
1 6 . 8 1
9 . 7 5
0 . 8 1
—
—
—
1 0 . 1 6
1 3 . 1 6
HANDLE
USE WITH
SPACE OCCUPIED
WHEN
WHEN
WHEN
WHEN
WHEN
MECHANISM
CIRCUIT BREAKER
F
G
K
H=60.12
H=72.12
H=72.12
H=84.12
H=90.12
WB
WB
WB
WB
WB
E AT O N C U T L E R - H A M M E R T Y P E S M S A F E T Y H A N D L E M E C H A N I S M S
†
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & MODULAR
(PAGES F28-F29 & F45-F46)
(PAGES F32-F49)
COMPLETE OPERATOR
AMP
FRAME
BREAKER
BREAKER
MECHANISM
RATING
TYPE
HEIGHT
WIDTH
F1S03
2 2 5 A
F F r a m e : E H D , F D B , F D , H F D
6 . 0 0
4 . 1 2
F1S03
1 5 0 A
F F r a m e : H M C P
6 . 0 0
4 . 1 2
F2S03
2 5 0 A
J F r a m e : J D B , J D , H J D , J D C
1 0 . 0 0
4 . 1 2
F2S03
2 5 0 A
J F r a m e : H M C P
1 0 . 0 0
4 . 1 2
F3S03
4 0 0 A
K F r a m e : D K , K D B , K D , H K D
1 0 . 1 2
5 . 5 0
F3S03
4 0 0 A
K F r a m e : H M C P
1 2 . 4 5
5 . 5 0
F4S04
6 0 0 A
L F r a m e : L D , H L D , L D C
1 0 . 7 5
8 . 2 5
F4S04
6 0 0 A
L F r a m e : H M C P
1 2 . 5 0
8 . 2 5
F7S04
8 0 0 A
M F r a m e : M D , M D S
1 6 . 0 0
8 . 2 5
F5S04
1 2 0 0 A
N F r a m e : N D , H N D , N D C
1 6 . 0 0
8 . 2 5
F6S04
2 5 0 0 A
R F r a m e : R D , C R D , R D C
1 6 . 0 0
1 5 . 5 0
EATON CUTLER-HAMMER FLEX SHAFT
™
OPERATOR MECHANISMS
• Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism.
• The last digit of the catalog number denotes the length of shaft (F1S03 = 3-foot shaft). The F, J, K frame Flex Shafts
™
are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths.
Space Occupied by Disconnect
• The Flex Shaft
™
system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism.
• Refer to National Electrical Code
®
article 430-10(b) for wiring space "WB" required for line side conductors.
• Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4-inch min. bending
radius for the Flex Shaft.
™
• Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "WB" and location "G"
as selected from right to left.
† For Two Door Floor-Mount NEMA 12
“E” =
7.31 when “H” = 60.12 for up to type SM200
(Pages F28-F29 & F45-F46)
“E” = 12.81 when “H” = 72.12 for up to type SM200
“E” = 6.88 when “H” = 60.12 for type SM200 and larger
“E” = 12.38 when “H” = 72.12 for type SM200 and larger
For Heavy Duty Freestanding
“E” = 11.31 when “H” = 72.12 for up to type SM200
and Modular Enclosures
“E” = 16.81 when “H” = 84.12 for up to type SM200
(Pages F32 - F49)
“E” = 19.81 when “H” = 90.12 for up to type SM200
“E” = 10.88 when “H” = 72.12 for type SM200 and larger
“E” = 16.38 when “H” = 84.12 for type SM200 and larger
“E” = 19.38 when “H” = 90.12 for type SM200 and larger
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S