Wiegmann WAX-MSSN4 Series User Manual
Page 25

A B N 1 2 F I X E D D E P T H S E R I E S E N C L O S U R E S
N E M A 1 2 F L A N G E D S I N G L E D O O R D I S C O N N E C T
F25
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
Allen-Bradley
When using a Bulletin 1494F disconnect
switch, order:
* 1. A disconnect switch (30A, 60A,
or 100A)
2. A fuse block adapter, if required
2. Line and load connectors, if required
**4. Door hardware (Bulletin 1494F-L1 for
2-point latching, or Bulletin 1494F-L2
and 1494F-L3 for 3-point latching)
When using a Bulletin 1494D circuit
breaker operating mechanism, order:
1. A circuit breaker (C-H)
2. An operating mechanism
3. A slide mechanism
**4. Door hardware Bulletin 1494F-L1 for
2-point latching, or Bulletin 1494F-L2
and 1494F-L3 for 3-point latching)
PLEASE NOTE:
1. Operator adapter plates are not required
with enclosures on page F61.
2. Various other switch accessories and
circuit breaker accessories are available
from disconnect manufacturers. The
above information is subject to change
without notice. Please contact
Hubbell/Wiegmann or the disconnect
manufacturer if there are further ques-
tions.
3. The “Space Occupied” tables (page
F26) are based upon information sup-
plied by the disconnect manufacturer.
Hubbell/Wiegmann does not assume
responsibility for the accuracy of these
dimensions.
* Items available from disconnect manufacturer as complete kits.
**Enclosure “H” dimension less than 40" (1016mm) requires a 2-point door hardware (one Allen-Bradley
catalog number 1494F-L1). Enclosures with an “H” dimension of 40.00-inches or more require a 3-
point door hardware (one Allen-Bradley catalog number 1494F-L2 and one catalog number 1494F-L3.
E
F
2.63
1.31
1.50
or Stiffener Locations.
mension exceeds 17".
er 40" high require
rdware and enclosures
rger require 3-point
TOP HOLE IN
R.H. FLANGE.
WB
G
THIS SPACE IS OCCUPIED
BY DISCONNECT SWITCH
AND FUSE CLIP (IF USED)
OR CIRCUIT BREAKER.
C
L
Space Occupied by Disconnect
E = 3.84 when Depth = 8.00
E = 6.75 when Depth = 10.00
E = 9.50 when Depth = 12.00
(Except enclosures for 200 amp switches)
E = 9.50 when Depth = 16.00
E = 10.50 when Depth = 12.00
(Except enclosures for 200 amp switches)
WB = Wiring Space
See page F26 for various brands of discon-
nects for “F”, “G” & “WB” dimensions.
Disconnects will occupy space on panel
shown by dimensions “E”, “F” & “G”. Wiring
space “WB” is available when disconnect is
installed in the enclosure.
Refer to National Electrical Code
®
article
430-10(b) for wiring space required for line
side conductors to be connected to discon-
nect. Verify your application to determine if
wiring space is adequate.
DISCONNECT ORDERING INFORMATION
When ordering wall-mounted disconnects from the following manufacturer, be sure to order
all of the necessary items. Order the following items from the disconnect manufacturer.