Wiegmann WAX-MSSN4 Series User Manual

Page 31

Advertising
background image

Allen-Bradley

When using a Bulletin 1494F flange-mounted
disconnect switch, order:

1. A disconnect switch

2. A fuse block adapter, if required

3. Line and load connectors, if required

When using a Bulletin 1494D flange-mounted
operator for a circuit breaker, order:

1. A circuit breaker

2. A flange-mounted operating mechanism

3. A slide mechanism

When using a Bulletin 1494V disconnect
switch, order:

* 1. A disconnect switch

* 2. An operating handle

* 3. A connecting rod (long)

* 4. A trailer fuse block kit, if required

* 5. A fuse clip kit, if required

6. Line and load connectors, if required

When using a Bulletin 1494V circuit
breaker operating mechanism, order:

1. A circuit breaker

2. A circuit breaker operating mechanism

3. An operating handle

4. A connecting rod (long)

An optional Allen-Bradley channel support kit
is recommended when Allen-Bradley Bulletin
1494V devices are installed in 72.12" (1832mm)
high enclosures with operating handle mounted
on centerpost.

ABB Controls

When using a disconnect switch, order:

1. A flange operated switch (fusible or

non-fusible)

2. A shaft [DSFHS-12 for 12.12” (308mm)

deep or DSFHS-17 for 18.12” (460mm)
deep enclosures; in 24.12" (613mm)
deep enclosures a platform must be
used with shaft]

3. A handle (DSFHN-HS12)

When using a circuit breaker, order:

1. A circuit breaker (ABB)

* 2. An operating mechanism

* 3. A shaft [FHS-12 for 12.12” (308mm)

deep or FHS-17 for 18.12” (460mm)
deep enclosures; in 24.12" (613mm)
deep enclosures a platform must be
used with shaft]

* 4. Handle mechanism (FHN-HS12)

Eaton Cutler-Hammer

When using a Type C361 disconnect switch,
order:

* 1. A disconnect switch with an

operating mechanism

* 2. An operating handle (C361H1 or

C361H3)

When using a Type C371 circuit breaker
operating mechanism with a circuit breaker,
order:

1. A circuit breaker

* 2. An operating mechanism

* 3. An operating handle

When using a Type SM handle mechanism,
order:

1. A circuit breaker

2. A type SM handle mechanism

When using a Flex Shaft

handle mechanism,

order:

1. A circuit breaker

2. A complete Flex Shaft

handle

mechanism

General Electric

When using a disconnect switch, order:

1. A disconnect switch (Type QMR or QMW)

2. A fuse clip kit or no-fuse kit

3. A flange handle (STDA1 or STDA2)

4. A variable depth operating mechanism

5. An extended length drive rod

(if required)

When using a circuit breaker, order:

1. A circuit breaker

2. A flange handle (STDA1 or STDA2)

3. A variable depth operating mechanism

4. An extended length drive rod (if required)

When optional General Electric Flange
Stiffener Kit (catalog number TDSR) is recom-
mended when General Electric Type TDA
devices are installed in 72.12" (1832) high
enclosures with operating handle mounted on
centerpost. Use with TDOM1, TDOM2,
TDOM3, S100M1A, and S100M3 operating
mechanisms.

When using a circuit breaker with a Spectra
Flex

cable operator, order:

1. A circuit breaker

2. A flange-mounted handle mechanism

3. A breaker-mounted mechanism

4. An operating cable

Siemens ITE Max-Flex

When using a disconnect switch, order:

1. A basic switch (right-hand)

2. A fuse or no-fuse kit

* 3. FHOHS flange-mounted handle

* 4. Switch operator

* 5. FHOECO36 cable for 12.12" (308mm)

deep enclosures or FHOECO48 for
18.12 (460mm) and 24.12" (613mm)
deep enclosures

When using a circuit breaker, order:

1. A circuit breaker

2. Pressure wire connectors

* 3. A flange-mounted handle

* 4. A circuit breaker operator mechanism

* 5. An operating cable [12.12" (308mm)

deep or 18.12 (460mm) deep enclosures
accept 36.00" (914mm) or 48.00 (1219mm)
cables; 24.12" (613mm) deep enclo-
sures require a 48.00" (1219mm) cable]

* These items are available from Siemens ITE Max-Flex

ITE as a complete mechanism with a 36.00" (914mm)
operating cable only. Order items separately when
using a 48.00" (1219mm) operating cable.

Schneider Square D

®

When using a disconnect switch, order:

1. A disconnect switch with operating

mechanism

2. A universal handle mechanism

3. A long operating rod, if required

When using a circuit breaker, order:

1. A circuit breaker

2. An operating mechanism

3. A universal handle mechanism

4. A long operating rod, if required

When using a Class 9422 Type “T” disconnect
switch with a cable mechanism, order:

1. A disconnect switch with operating

mechanism (Class 9422 Type T)

2. A handle mechanism (Class 9422

Type A-1)

3. A cable mechanism (Class 9422 CFT_O)

3-, 5-, or 10-foot

When using a circuit breaker with a cable
mechanism, order:

1. A circuit breaker (Schneider Square D

®

)

2. A handle mechanism (Class 9422

Type A-1)

3. A cable mechanism (Class 9422 CFT_O)

3-, 5-, or 10-foot

An optional Schneider Square D

®

Channel

Flange Support Kit (catalog number 9422-C1)
is recommended when some Schneider
Square D

®

devices are installed in 72.12"

(1832mm) high enclosures with operating han-
dle mounted on centerpost.

PLEASE NOTE:

1. Various other switch accessories and circuit breaker accessories are available from disconnect

manufacturers. The above information is subject to change without notice. Please contact
Hubbell-Wiegmann or the disconnect manufacturer if there are further questions.

2. The “Space Occupied” tables (pages F51-F60) are based upon information supplied by dis-

connect manufacturers. Hubbell-Wiegmann does not assume responsibility for the accuracy of
these dimensions.

* Items available from disconnect manufacturer as complete kits.

DISCONNECT ORDERING INFORMATION

When ordering wall-mounted disconnects from the various manufacturers, be sure to order
all of the necessary items. Each company has a different system, so care is required. Order
the following items from the disconnect manufacturer.

www.hubbell-wiegmann.com

Data Subject To Change Without Notice

W A X - U & W A C P X - U S E R I E S E N C L O S U R E S

N E M A 1 2 F L O O R - M O U N T D I S C O N N E C T

F31