Wiegmann WAX-MSSN4 Series User Manual
Page 60

F60
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
TYPE
AMP
FUSE
FUSE
DISCONNECT DISCONNECT
TWO DOOR
FREESTANDING MODULAR
NUMBER
RATING
CLIP
CLASS
HEIGHT X
WIDTH Y
FLOOR-MOUNT
TCN-30C
3 0 A
N o f u s e
—
5 . 9 0
6 . 2 0
TCF-30C
3 0 A
3 0 A - 2 5 0 V
H , K , R
7 . 5 0
6 . 2 0
TCF-33C
3 0 A
3 0 A - 6 0 0 V
H , K , R
1 0 . 1 5
6 . 2 0
TCF-33C
3 0 A
6 0 A - 2 5 0 V
H , K , R
8 . 1 5
6 . 2 0
TCF-33C
3 0 A
3 0 A - 6 0 0 V
J
7 . 5 0
6 . 2 0
TDN-60C
6 0 A
N o f u s e
—
5 . 9 0
6 . 2 0
F o r e n c l o s u r e s
TDF-60C
6 0 A
3 0 A - 6 0 0 V
H , K , R
1 0 . 1 5
6 . 2 0
t h a t a c c e p t
TDF-60C
6 0 A
6 0 A - 2 5 0 V
H , K , R
8 . 1 5
6 . 2 0
t h e s e d e v i c e s ,
TDF-63C
6 0 A
6 0 A - 6 0 0 V
H , K , R
1 0 . 6 5
6 . 2 0
s e e p a g e s F 2 8 - F 2 9
TDF-63C
6 0 A
6 0 A - 6 0 0 V
J
7 . 5 0
6 . 2 0
& F 4 5 - F 4 6
TEN-10C
1 0 0 A
N o f u s e
—
5 . 9 0
6 . 2 0
TEF-10C
1 0 0 A
1 0 0 A - 2 5 0 V
H , K , R
1 0 . 3 5
6 . 2 0
TEF-10C
1 0 0 A
1 0 0 A - 6 0 0 V
H , K , R
1 0 . 3 5
6 . 2 0
TEF-10C
1 0 0 A
1 0 0 A - 6 0 0 V
J
1 0 . 3 5
6 . 2 0
SCHNEIDER SQUARE D
®
CLASS 9422 DISCONNECT SWITCHES USED WITH CABLE MECHANISM 9422-CFT30 AND 9422-A1 HANDLE MECHANISM
CABLE TYPE
CIRCUIT B
CIRCUIT B
CIRCUIT BREAKER
CIRCUIT BREAKER
TWO DOOR
FREESTANDING MODULAR
SWITCH
AMP RATING
FRAME TYPE
HEIGHT X
WIDTH Y
FLOOR-MOUNT
9422 CGJ30
7 5 A
G J L
4 . 7 5
3 . 5 0
9422 CGJ30
1 0 0 A
G J L
4 . 7 5
3 . 5 0
9422 CFA30
1 0 0 A
FA J , F H L
6 . 0 0
4 . 5 0
9422 CKA30
2 5 0 A
K A L , K H L
8 . 0 0
4 . 5 0
9422 CLA30
4 0 0 A
L A L , L H L , Q 4 L
1 1 . 0 0
6 . 0 0
S C H N E I D E R S Q U A R E D
®
C L A S S 9 4 2 2 C A B L E M E C H A N I S M F O R C I R C U I T B R E A K E R S
Use switches listed above with appropriate cable mechanism and 9422-A1 handle mechanism. Cable operators are available in 3-foot, 5-foot, and 10-foot lengths.
Numbers shown (30) are for 3-foot cables.
Use cable mechanism with appropriate circuit breaker and 9422-A1 handle mechanism. Cable operators are available in 3-foot, 5-foot, and 10-foot lengths.
Numbers shown (30) are for 3-foot cables.
Space Occupied by Disconnect Switch or Circuit Breaker
• Schneider Square D
®
cable mechanisms allows disconnect devices to be positioned independent from the flange-mounted handle mechanism.
• Refer to National Electrical Code
®
article 430-10(b) for wiring space “WB” required for line side conductors.
• Choose cable mechanism length based on placement of disconnect in enclosure. See Schneider Square D
®
instruction Bulletin for minimum bend radius
for cable.
• Space occupied by disconnect is determined by overall height “X”, width “Y”, wire bend space “WB” and location “G” as selected from right to left.
F o r e n c l o s u r e s t h a t
a c c e p t t h e s e d e v i c e s ,
s e e p a g e F 2 8 - F 2 9 &
F 4 5 - F 4 6
F o r e n c l o s u r e s t h a t a c c e p t
t h e s e d e v i c e s ,
s e e p a g e s F 3 2 - F 4 9
†For Two Door Floor-Mount NEMA 12
“E” =
7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46)
“E” = 13.38 when “H” = 72.12
For Heavy Duty Freestanding
“E” = 11.88 when “H” = 72.12
and Modular Enclosures
“E” = 17.38 when “H” = 84.12
(Pages F32 - F49)
“E” = 20.38 when “H” = 90.12
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S
D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N
F o r e n c l o s u r e s
t h a t a c c e p t t h e s e d e v i c e s ,
s e e p a g e s F 3 2 - F 4 9