Wiegmann WAX-MSSN4 Series User Manual
Page 54

F54
www.hubbell-wiegmann.com
Data Subject To Change Without Notice
C361NC
3 0 A
N o f u s e
—
5 . 7 5
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SC21
3 0 A
3 0 A - 2 5 0 V
H , K , R
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SC61
3 0 A
6 0 A - 2 5 0 V
H , K , R
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SC61
3 0 A
3 0 A - 6 0 0 V
H , J , K , R
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361ND
6 0 A
N o f u s e
—
5 . 7 5
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SD22
6 0 A
6 0 A - 2 5 0 V
H , K , R
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SD22
6 0 A
3 0 A - 6 0 0 V
J
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SD62
6 0 A
6 0 A - 6 0 0 V
H , K , R
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361SD62
6 0 A
6 0 A - 6 0 0 V
J
8 . 3 8
7 . 5 5
0 . 5 6
6 . 5 0
1 2 . 5 0
1 0 . 5 0
1 6 . 5 0
1 9 . 5 0
C361NE
1 0 0 A
N o f u s e
—
5 . 5 6
9 . 0 7
0 . 5 6
6 . 0 6
1 2 . 0 6
1 0 . 0 6
1 6 . 0 6
1 9 . 0 6
C361SE263
1 0 0 A
1 0 0 A - 2 5 0 V
H , K , R
1 0 . 3 1
9 . 0 7
0 . 5 6
6 . 0 6
1 2 . 0 6
1 0 . 0 6
1 6 . 0 6
1 9 . 0 6
C361SE263
1 0 0 A
1 0 0 A - 2 5 0 V
H , K , R
1 0 . 3 1
9 . 0 7
0 . 5 6
6 . 0 6
1 2 . 0 6
1 0 . 0 6
1 6 . 0 6
1 9 . 0 6
C361SE263
1 0 0 A
1 0 0 A - 6 0 0 V
J
1 0 . 3 1
9 . 0 7
0 . 5 6
6 . 0 6
1 2 . 0 6
1 0 . 0 6
1 6 . 0 6
1 9 . 0 6
C361NF
2 0 0 A
N o f u s e
—
1 3 . 0 6
1 0 . 1 2
0 . 5 6
4 . 0 6
1 0 . 0 6
8 . 0 6
1 4 . 0 6
1 7 . 0 6
C361SF264
2 0 0 A
2 0 0 A - 2 5 0 V
H , K , R
1 3 . 0 6
1 0 . 1 2
0 . 5 6
4 . 0 6
1 0 . 0 6
8 . 0 6
1 4 . 0 6
1 7 . 0 6
C361SF264
2 0 0 A
2 0 0 A - 6 0 0 V
H , K , R
1 3 . 0 6
1 0 . 1 2
0 . 5 6
4 . 0 6
1 0 . 0 6
8 . 0 6
1 4 . 0 6
1 7 . 0 6
TYPE
AMP
FUSE
FUSE
SPACE OCCUPIED
WHEN
WHEN
WHEN
WHEN
WHEN
NUMBER
RATING
CLIP
CLASS
F
G
K
H=60.12
H=72.12
H=72.12
H=84.12
H=90.12
WB
WB
WB
WB
WB
E AT O N C U T L E R - H A M M E R C 3 6 1 D I S C O N N E C T S W I T C H E S
†
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & MODULAR
(PAGES F28-F29 & F45-F46)
(PAGES F32-F49)
C371E
2 2 5 A
F F r a m e : E H D , F D B , F D , H F D , F D C
6 . 0 0
5 . 6 2
0 . 5 6
7 . 6 2
1 3 . 6 2
1 1 . 6 2
1 7 . 1 2
2 0 . 1 2
C371E
1 5 0 A
F F r a m e : H M C P
6 . 0 0
5 . 6 2
0 . 5 6
7 . 6 2
1 3 . 6 2
1 1 . 6 2
1 7 . 1 2
2 0 . 1 2
C371F
2 2 5 A
J F r a m e : J D B , J D , H J D , J D C
8 . 9 4
8 . 1 2
0 . 5 6
7 . 5 0 *
1 3 . 0 0
1 1 . 4 4
1 6 . 9 4
2 0 . 0 0
C371F
2 2 5 A
J F r a m e : H M C P
1 0 . 9 4
8 . 1 2
0 . 5 6
7 . 5 0 *
1 3 . 0 0
1 1 . 4 4
1 6 . 9 4
2 0 . 0 0
C371F
4 0 0 A
K F r a m e : D K , K D B , K D , H K D
9 . 7 5
8 . 1 2
0 . 5 6
7 . 0 0 *
1 3 . 0 0
1 1 . 0 0
1 7 . 0 0
2 0 . 0 0
C371F
4 0 0 A
K F r a m e : H M C P
9 . 7 5
8 . 1 2
0 . 5 6
7 . 0 0 *
1 3 . 0 0
1 1 . 0 0
1 7 . 0 0
2 0 . 0 0
C371G
6 0 0 A
L F r a m e : L D , H L D , L D C
8 . 4 4
1 2 . 0 0
0 . 5 6
—
1 0 . 8 8 * *
9 . 3 8
1 5 . 3 8
1 8 . 3 8
C371G
6 0 0 A
L F r a m e : H M C P
8 . 4 4
1 2 . 0 0
0 . 5 6
—
1 0 . 8 8 * *
9 . 3 8
1 5 . 3 8
1 8 . 3 8
C371K
8 0 0 A
M F r a m e : M D , M D S
1 0 . 2 5
1 2 . 0 0
0 . 5 6
—
—
—
1 1 . 8 1
1 4 . 8 1
C371K
1 2 0 0 A
N F r a m e : N D , H N D , N D C
1 0 . 2 5
1 2 . 0 0
0 . 5 6
—
—
—
1 1 . 8 1 * * *
1 4 . 8 1
MECHANISM AMP
FRAME TYPE
SPACE OCCUPIED
WHEN
WHEN
WHEN
WHEN
WHEN
RATING
F
G
K
H=60.12
H=72.12
H=72.12
H=84.12
H=90.12
WB
WB
WB
WB
WB
E AT O N C U T L E R - H A M M E R C 3 7 1 C I R C U I T B R E A K E R O P E R AT O R S
†
WIRE BEND SPACE “WB” ABOVE DISCONNECT
TWO DOOR FLOOR-MOUNT
FREESTANDING & MODULAR
(PAGES F28-F29 & F45-F46)
(PAGES F32-F49)
* Available wire bend space "WB" does not allow cable sizes larger than 4/0 AWG in a 60.12-inch tall enclosure.
** Available wire bend space "WB" does not allow cable sizes larger than 300 MCM.
*** Available wire bend space "WB" does not allow cable sizes larger than 350 MCM in a 90.12-inch tall enclosure when using 4 cable per terminal.
See National Electrical Code
®
, table 373-6(b) for more information. Available wire bend space “WB” is insufficient for use with breakers equipped
with TA1201NB1 terminals.
†For Two Door Floor-Mount NEMA 12
“E” =
7.88 when “H” = 60.12
(Pages F28-F29 & F45-F46)
“E” = 13.38 when “H” = 72.12
For Heavy Duty Freestanding
“E” = 11.88 when “H” = 72.12
and Modular Enclosures
“E” = 17.38 when “H” = 84.12
(Pages F32 - F49)
E” = 20.38 when “H” = 90.12
F L O O R - M O U N T • F R E E S TA N D I N G • M O D U L A R S E R I E S E N C L O S U R E S
D I S C O N N E C T S PA C E O C C U P I E D & AVA I L A B L E W I R I N G S PA C E I N F O R M AT I O N