Wiegmann WAX-MSSN4 Series User Manual

Page 40

Advertising
background image

Accessories
• See pages J1-J22
• Blank adapter plates on pages F61

IMPORTANT
• Disconnect switch or circuit breakers, operat-

ing handle and operating mechanism are not
furnished with enclosure and must be ordered
separately from the disconnect manufacturer

• Operator adapter plates are required with the

modular flange disconnect enclosure only and
must be purchased separately. Modular non-
disconnect enclosures do not require a opera-
tor adapter plate. See page F61 to select the
proper operator adapter for the brand and
type of disconnect being used

• Disconnect ordering information is located on

page F44

• Review space occupied by disconnect draw-

ings on page F43 and disconnect tables on
pages F51-F60 to determine if the disconnect
device you are using will fit the enclosure size
you have selected

A modular enclosure system consists of:
• A disconnect (master) enclosure
• Any quantity of slave enclosures
• Gasket kits to be used between enclosures
• End plate
• An operator adapter plate or blank adapter

plate

• Disconnect device (order from disconnect

manufacturer)

Single and Two Door Enclosures
• Left side is open (see drawings on pages F41

and F42)

• Master door hinged on left
• Master door activates mechanical interlock

which prevents slave enclosures from being
opened first

• Doors may be closed in any order

Single and Two Door Slave Enclosures
• Both sides are open (see drawings on pages

F41 and F42)

• Door cannot be opened until master enclo-

sure is opened or the interlock is defeated

W M O D S E R I E S E N C L O S U R E S
N E M A 1 2 M O D U L A R F R E E S TA N D I N G D I S C O N N E C T

F E AT U R E S - S P E C I F I C AT I O N S

UL File E64791

CSA File LL66078

www.hubbell-wiegmann.com

Data Subject To Change Without Notice

Applications
Modular single-door and double-door Modular
free-standing enclosures are designed to be
bolted together in a variety of lengths and com-
binations to meet the customer’s specific appli-
cation. Modular disconnects enclosures are
designed to house the following flange-mounted
disconnect switches and circuit breakers:
The Wiegmann universal cutout is used in large
freestand and floorstand enclosures. Operator
Adapter Kits are required in order to install the
various manufacturers’ hardware. Note that 400
A (or greater) disconnect switches and 600 A (or
greater) circuit breakers need to use the “Large”
or “High Amp” cutout, which is provided in the
WA21ABVA kit for Allen-Bradley variable-depth
disconnect switches or the WA21ITE kit for
Siemens ITE Max-Flex

(and select other manu-

facturers) flex-cable devices. The “Large” or
“High Amp” cutout accepts the larger operating
handle whose mounting hole centers are 6.500-
in. apart.

Allen-Bradley

• 1494V disconnect switches with flange-mount

variable depth operating mechanisms and
1494V flange-mounted variable depth operat-
ing mechanisms for circuit breakers

• 140U flexible cable operating mechanisms and

140U molded case circuit breakers

• 1494C cable-operated disconnect switches

with flange-mount handles

• 194RC cable-operated flange-mount handles

for use with the NFPA 79 compliant 194R IEC
rotary disconnect switches

Allen-Bradley 1494V-R1, -R2 and -W2 operating
handles and Allen-Bradley 1494F disconnect
devices or 1494D circuit breaker operators will
NOT fit these enclosures.
• ABB Controls flange-mounted variable

depth operating mechanisms for disconnect
switches and circuit breakers

• Eaton Cutler-Hammer Type C361 discon-

nect switches and operating mechanisms,
and Type C371 circuit breaker operating
mechanisms. Also Type SM safety handle

mechanisms and Flex Shaft

handle oper-

ators for circuit breakers

• General Electric Type STDA flange han-

dles and variable depth operating mecha-
nisms for disconnect switches and circuit
breakers. Also Spectra Flex

cable opera-

tors for circuit breakers

• Siemens ITE Max-Flex

flange-mounted

variable depth operating handles for dis-
connect switches and circuit breakers

• Schneider Square D

®

disconnect switches

and circuit breakers used with Class 9422
flange-mounted variable depth operating
mechanisms or cable mechanisms
These enclosures will not receive
Schneider Square D

®

Class 9422 bracket-

mounted disconnect devices or Class
9422TG1 or TG2 devices.

Construction
• Bodies and doors fabricated from 10 ga. steel
• Removable 10-gauge back panels are includ-

ed and mounted on collar studs

• Continuously welded seams ground smooth
• Body stiffeners are provided for extra rigidity
• Door and side openings are flanged to pro-

vide extra strength and smooth edges

• Heavy duty lifting eyes and provisions for fluo-

rescent lighting are provided

• Heavy gauge continuous hinges
• Grounding provisions provided
• 3-point padlocking handle on all doors
• Doors are supplied with a poured-in-place

polyurethane gasket

• Print pocket is provided
• Panel supports
• Mechanical interlocks come standard on each

enclosure. Parts required to connect interlock sys-
tem between adjacent enclosures are provided

Finish
• ANSI 61 gray polyester powder inside and out

over phosphatized surfaces

• Back panels are white polyester powder over

phosphatized surfaces

WMOD72X4018U

F40

Industry Standards
UL 508, Type 12
CSA Certified, Type 12
NEMA/EEMAC Type 12

Advertising