<4. Installing Impulse Piping>

27

IM 01C25A01-01E

• A variety of process piping-mounted stop valves are

available according to the type of connection (flanged,
screwed, welded), construction (globe, gate, or ball
valve), temperature and pressure.
Select the type of valve most appropriate for the
application.

Gas flow measurement

Liquid flow measurement

Union or flange

Union or flange

Stop valve

Stop valve

Manifold

Manifold

Process piping

Process piping

F0410.ai

Figure 4.10 Process Piping Connection Examples