<8. Parameter Summary>

44

IM 01C25A01-01E

No. Parameter name

Item

R/W

*1

Content

Default value

Applicable model

U

pl

oa

d

da

ta

F

P

L

G

ALARM SET

Alarm setting

G10 P AL MODE

Alert mode

W

INHIBIT, HI. AL DETECT,

LO. AL DETECT, or HI/LO.

AL DETECT

INHIBIT

G11 P HI. AL VAL

High side alert value

W

-32000 to 32000, unit

specified in C20

100.000 kPa

G12 P LO. AL VAL

Low side alert value

W

-32000 to 32000, unit

specified in C20

-100.000 kPa

G20 SP AL MODE

Static pressure alert

mode

W

INHIBIT, HI. AL DETECT,

LO. AL DETECT, or HI/LO.

AL DETECT

INHIBIT

G21 SP HI. AL VAL

High side alert value of

SP*

2

W

-32000 to 32000, unit

specified in D30

G22 SP LO. AL VAL

Low side alert value

of SP

W

-32000 to 32000, unit

specified in D30

0.00000 MPa

G30 T AL MODE

Temperature alert mode

W

INHIBIT, HI. AL DETECT,

LO. AL DETECT, or HI/LO.

AL DETECT

INHIBIT

G31 T HI. AL VAL

High side alert value of

temperature

W

-50 to 130

120 degC

G32 T LO. AL VAL

Low side alert value of

temperature

W

-50 to 130

-40 degC

G50 AUTO RECOVER Auto-recover from

sensor error

W

OFF or ON

ON

G60 SELF CHECK

Self-diagnostics

R

See A60

H

AUTO SET

Automatic setup

H10 AUTO P LRV

Lower range value auto

setup

W

-32000 to 32000, unit

specified in C20

As specified

H11 AUTO P URV

Upper range value auto

setup

W

-32000 to 32000, unit

specified in C20

As specified

H20 AUTO SP LRV

SP lower range value

auto setup

W

-32000 to 32000, unit

specified in D30

0.00000 MPa

H21 AUTO SP URV

SP upper range value

auto setup*

2

W

-32000 to 32000, unit

specified in D30

H60 SELF CHECK

Self-diagnostics

R

See A60

I

DISP SET

Display setting

I10

DISP OUT1

LCD output 1

W

PRES, PRES %, ENGR.

PRES, SP, or SP %

PRES %

I11

DISP OUT2

LCD output 2

W

PRES, PRES %, ENGR.

PRES, SP, SP %, or ---

---

I12

DISP OUT3

LCD output 3

W

See I11

---

I13

DISP OUT4

LCD output 4

W

See I11

---

I20

P DISP MODE

% display mode

W

LINEAR or SQUARE ROOT LINEAR

I21

PRES % RESO

% display resolution

W

NORMAL or HIGH

RESOLUTION

NORMAL

I30

ENGR. UNIT

User set engineering

unit

W

8 alphanumeric characters

I31

EASY EU SET

Engineering unit select

W

I32

ENGR. EXP

Exponents

W

---, Ч10, Ч100, Ч1000

---

I33

ENGR. LRV

User set lower range

limit

W

-32000 to 32000, unit

specified in I30

0.00

I34

ENGR. URV

User set upper range

limit

W

-32000 to 32000, unit

specified in I30

100.00

I35

ENGR. POINT

Decimal place of user

set

W

0 to 4

1

I40

BAR INDICATR

Bar indicator

W

OFF or ON

ON

I41

POWER ON INF

Display when powering

on

W

OFF or ON

ON

I60

SELF CHECK

Self-diagnostics

R

See A60

*1: R/W: R = Read only, W = Read & Write

*2:

The default value shows MWP (Maximum working pressure) of the capsule.

Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user’s manual.