<3. Installation>

19

IM 01C25A01-01E

3.2.1 EJ210

The transmitter is mounted on a process using its
high pressure side flange as shown in Figure 3.5. The
customer should prepare the mating flange, gasket, stud
bolts and nuts.

F0305.ai

Gasket

Stud bolt

Nut

Figure 3.5

EJ210 Mounting

3.2.2 EJ118 and EJ438

Mount the diaphragm seals using the flanges as shown in
Figure 3.6. The mating flange, gasket, bolts and nuts are
to be procured by the customer.

Nut

Flange

Diaphragm

ød

Gasket

F0306.ai

Bolt

The product is

shipped with these

parts assembled.

Correctly install the diaphragm

seals on the high and low pressure

sides of the process (The label on

each diaphragm seal is marked

HIGH or LOW).

Figure 3.6

Mounting the Diaphragm Seals

3.3 Diaphragm Seals Installation

Consideration

IMPORTANT

• When measuring the liquid level of the tank, the

minimum liquid level (zero point) must be set to a
level at least 50 mm above the center of the high
pressure side diaphragm seal (see Figure 3.7).

• Correctly install the diaphragm seals on the high

and low pressure sides of the process, checking
the label on each seal.

• To avoid measuring error duets temperature

difference between the two diaphragm seals,
capillary tube must be bound together. The
capillary tube must be securely fixed to the tank
wall to prevent movement by wind or vibration.
If the capillary tube is too long, loosely coil the
extra tube portion (coil diameter of 300 mm or
more) and secure the coiled tube with a clamp.

F0307.ai

50 mm minimum

Minimum

liquid level

High

pressure

side

Low

pressure

side

The transmitter should

be installed as low as

possible below the

position where the high

pressure side

diaphragm seal is

installed.

Install the sealed diaphragm

so that the shank positions

downward.

IMPORTANT

Figure 3.7

Installing the Diaphragm Seals to a

Tank

In

sta

lla

tio

n

3