2 impulse piping connection examples, Impulse piping connection examples, Important – Yokogawa EJX115A User Manual

Page 27

Advertising
background image

<4. Installing Impulse Piping>

25

IM 01C25A01-01E

(4) Temperature Difference Between Impulse

Piping (for differential pressure

transmitters)

If there is a temperature difference between the high
and low impulse lines, the density difference of the fluids
in the two lines will cause an error in the measurement
pressure. When measuring flow, impulse lines must be
routed together so that there is no temperature difference
between them.

(5) Condensate Pots for Steam Flow

Measurement (for differential pressure

transmitters)

If the liquid in the impulse piping repeatedly condenses
or vaporizes as a result of changes in the ambient or
process temperature, this will cause a difference in the
fluid head between the high pressure and low pressure
sides. To prevent measurement errors due to these head
differences, condensate pots are used when measuring
steam flow.

(6) Preventing Wind Speed Effects in Very Low

Differential Pressure Measurement

(for differential pressure transmitters)

IMPORTANT

When using a differential pressure transmitter to
measure very low pressures (draft pressure), the low
pressure connection port is left open to atmospheric
pressure (the reference pressure).
Any wind around the differential pressure transmitter
will therefore cause errors in the measurement. To
prevent this, it will be necessary either to enclose the
transmitter in a box, or to connect a impulse line to
the low pressure side and insert its end into a wind
excluding pot (cylindrical with a base plate).

(7) Preventing Freezing

If there is any risk that the process fluid in the impulse
piping or transmitter could freeze, use a steam jacket or
heater to maintain the temperature of the fluid.

NOTE

After completing the connections, close the valves on
the process pressure taps (main valves), the valves at
the transmitter (stop valves), and the impulse piping
drain valves, so that condensate, sediment, dust and
other extraneous material cannot enter the impulse
piping.

4.2 Impulse Piping Connection

Examples

Figure 4.6, 4.7, and 4.8 shows examples of typical
impulse piping connections. Before connecting the
transmitter to the process, study the transmitter
installation location, the process piping layout, and
the characteristics of the process fluid (corrosiveness,
toxicity, flammability, etc.), in order to make appropriate
changes and additions to the connection configurations.
Note the following points when referring to these piping
examples.

• If the impulse line is long, bracing or supports should

be provided to prevent vibration.

• The impulse piping material used must be compatible

with the process pressure, temperature, and other
conditions.

• A variety of process pressure tap valves (main valves)

are available according to the type of connection
(flanged, screwed, welded), construction (globe, gate,
or ball valve), temperature and pressure. Select the
type of valve most appropriate for the application.

Tee

3-valve

manifold

Drain valve

Orifice

Drain plug

Tap valve

Union

or flange

Liguid

Gas

Condensate pot

Steam

F0406.ai

Figure 4.6

Impulse Piping Connection Examples

(for differential pressure transmitters)

F0407.ai

Pipe (opened to atmosphere

at low pressure side)

Open Tank

Closed Tank

Tap valve

Union or flange

Vent plug

Tee

Drain valve

Drain plug

Figure 4.7

Impulse Piping Connection Examples

(EJ210)

In

sta

llin

g Im

pu

lse

P

ip

in

g

4

Advertising