Parameter summary, Important, For hart protocol revision 7, f – Yokogawa EJX115A User Manual

Page 42

Advertising
background image

<8. Parameter Summary>

40

IM 01C25A01-01E

8. Parameter Summary

NOTE

For HART protocol revision 7, F

OUNDATION

Fieldbus

and PROFIBUS PA communication types, and
EJX910A/EJX930A, please refer to manuals in the
attached CD-ROM.

IMPORTANT

If the transmitter is turned off within 30 seconds after
parameters have been set, the set data will not be
stored and the terminal returns to previous settings.

Menu Tree for HART Protocol Revision 5 (Except EJX910A and EJX930A)

1 Device setup

2 Pres

3 AO

4 LRV

5 URV

1 Process variables

2 Diag/Service

3 Basic setup

4 Detailed setup

5. Review

1 Pres

2 Pres %

3 AO

4 SP

5 SP %

6 Snsr temp

7 Engr Disp

8 Engr exp

9 Engr Unit

1 Status group 1

2 Status group 2

3 Status group 3

4 Status group 4

5 Status group 5

6 Status group 6

7 Status group 7

8 Status group 8

9 Status group 9

1 Keypad input

2 Apply values
1 D/A trim

2 Scaled D/A trim

3 Clear D/A trim
1 Pres Zero trim

2 Pres trim

3 P LTP

4 P UTP

5 Pres trim info.

1 Pres

2 Pres %

3 SP

4 Snsr temp

1 Pres

2 Pres %

3 Unit

4 Pres sensor trim
1 SP

2 SP %

3 SP Unit

4 A/G Select

5 SP H/L Select

6 SP sensor trim
7 SP setup

1 Pres

2 Pres %

3 AO

4 SP

5 SP %

6 Snsr temp

7 Engr Disp

8 Engr exp

9 Engr Unit

Digital Output

1 Loop test

2 D/A trim

3 Scaled D/A trim

4 Clear D/A trim

5 AO alm typ

6 Auto recover

7 AO lower limit

8 AO upper limit

1 Poll addr

2 Num req preams

3 Burst mode

4 Burst option

1 Pres Alert mode

2 Config Pres Alerts

3 SP Alart mode

4 Config SP Alerts

5 Temp Alert mode

6 Config Temp Alerts

7 DO Config

1 Disp Out 1

2 Disp Out 2

3 Disp Out 3

4 Disp Out 4

1 Universal rev

2 Fld dev rev

3 Software rev

1 S.C.

2 Num of points

3 Point setting

1 P LTD

2 P UTD

3 Clear P snsr trim

1 SP LTD

2 SP UTD

3 Clear SP snsr trim

1 Disp Pres % fnctn

2 Disp Pres % Reso

3 Pres disp point
1 Engr LRV

2 Engr URV

3 Engr exp

4 Engr Unit

5 Engr point

6 Set Engr Unit

7 Modify Engr Unit

1 Keypad input

2 Apply values

1 Date

2 Descriptor

3 Message

4 Write Protect

1 Static Pres trim

2 SP LTP

3 SP UTP

4 SP trim info.
1 Trim Who

2 Trim Date

3 Trim Loc

4 Trim Desc

1 Digital Output

2 DO Select

3 DO Signal type

4 DO Test

1 Pres Zero trim

2 Pres trim

3 P LTP

4 P UTP

5 Pres trim info.

1 Static Pres trim

2 SP LTP

3 SP UTP

4 SP trim info.

1 T.Z. Cmp mode

2 Temp Zero

1 SP range

2 SP Unit

3 SP Damp

4 SP A/G Setup

5 SP H/L Select

1 Tag

2 Date

3 Descriptor

4 Message

5 Model 1

6 Model 2

7 Model 3

8 Write Protect

9 Ext SW

Revision #s

Additional Info

1 Status

2 Self test

1 Re-range

2 Analog output trim

3 Pres sensor trim

4 SP sensor trim

5 Trim info.

1 Error log view

2 Error log Clear

1 Process variables

2 Re-range

3 Unit

4 Xfer fnctn

5 Pres Damp

6 Low cut

7 Low cut mode

8 H/L Swap

9 Bi-dir mode

Quick resp

T.Z. Cmp menu

S.C. menu

1 Process variables

2 Analog output

3 HART output

4 Process Alerts

1 Disp select

2 P disp condition

3 SP disp condition

4 Engr disp range

5 Bar Indicator
1 Field device info

2 Sensor information

3 Self test

1 Pressure sensor

2 SP sensor

3 Temp sensor

1 Keypad input

2 Apply values

1 Linear

2 Sq root

Linear

Zero
Normal

Reverse

1 Snsr temp

2 Amp temp

3 Temp Unit

1 Test device

2 Loop test

3 Calibration

4 Diag Parameters

5 Error log

Online Menu

(Device setup)

(Process variables)

(Diag/Service)

1 Tag

2 Unit

3 Re-range

4 Device information

5 Xfer fnctn
6 Pres Damp
7 Low cut
8 Low cut mode
9 H/L Swap

SP setup

(Basic setup)

1 Sensors

2 Signal condition

3 Output condition

4 Display condition

5 Device information

6 Test Key

(Detailed setup)

1 Keypad Input

2 Wrt protect menu

Hot Key

1 LRV

2 URV

3 Unit

4 LSL

5 USL

6 Min Span

1 Write protect

2 Enable wrt 10min

3 New password

4 Software seal

F0801-1.ai

See

A

(next page).

Advertising