Actions Using the Event

Action and

Remote Control Functions (/R1 and /PM1 Options)

1

2

3

4

5

6

7

8

9

10

11

12

App

Index

• Event action > Action

The action to be executed when an event occurs.

Settings

Description

Memory

-

Start

-

Stop

-

Trigger*

Can be specified when the DX is configured to record event data.

AlarmACK Cannot be specified when the event is set to

Relay, Switch, or Alarm.

Math

Can be specified on /M1 and /PM1 options.

MathStrt

Start computation. Can be specified on /M1 and /PM1 options.

MathStop

Stop computation. Can be specified on /M1 and /PM1 options.

Math rst

Reset computation. Can be specified on /M1 and /PM1 options.

SaveDisp

Can be specified when the DX is configured to record display data.

SaveEvt

Can be specified when the DX is configured to record event data.

Message

Set the message number to write the message and the destination. Set the

message destination to all groups (All) or a group number.

Snap

Snapshot

Rate1/2

Can be specified when the function for switching between the trend interval and

the secondary trend interval is enabled.

M.sample

Manual sampling

TimerRst

Cannot be specified when the event is set to

Timer.

Group

Specify the number of the group to be displayed.

Flag

Can be specified on /M1 and /PM1 options.

Time adj

Can be specified only when the event is set to

Remote.

PnlLoad*

Can be specified only when the event is set to

Remote.

Comment

Specify the comment text block number to display. This function is available for

release numbers 3 and later.

Favorite

Choose which registered display to switch to. This function is available for release

numbers 3 and later.

Setting

Description

Key

Performs the same operation as

pressing the favorite key.

Select>Favorite Screen No Displays the specified favorite screen.

* If you configure the settings so that the Favorite action and the Group action

occur at the same time, only the action whose event action number is largest will

be executed.

AlarmRst

This action can only be specified when using the double lock-in sequence of the

alarm annunciator function (see section 3.12), and the event is Remote, UserKey,

or Edge. This function is available for release numbers 3 and later.

* This action is not available on DXs with the /AS1 advanced security option.

7.1 Setting the Event Action Function (Including the remote control function of the /R1 and /PM1 options and

the USER key)

Advertising