Other communication errors – Yokogawa Removable Chassis DX1000N User Manual

Page 284

Advertising
background image

10-16

IM 04L41B01-01E

Other Communication Errors

An English error message is returned via the communication interface. It is not displayed
on the screen.

Code

Message

400

Input username.

Enter the name of a user that is registered on the DX and that is allowed to log in to the DX through communication.

401

Input password.

Enter the password.

402

Select username from ‘admin’ or ‘user’.

Select “admin” or “user” to specify the user level to connect to.

403

Login incorrect, try again!

The login failed. Enter the information again, starting with the user name.

404

No more login at the specified level is acceptable.

Connecting would cause the maximum number of simultaneous connections (administrator: 1, normal user: 2 or

setting: 1, monitoring: 2) to be exceeded. Connect to a different level, or exit by entering “quit.”

405

Input user ID.

Enter a user ID.

406

Select function from ‘setting’ or ‘monitor’.

Select “setting” (to connect to the setting function) or “monitor” (to connect to the monitoring function).

407

Password has expired. Please enter a new password.

The password has expired. Enter a new password.

408

Enter password again for confirmation.

Enter the password again for confirmation.

409

This password is not correct or was already used.

The password is incorrect or has already been used.

410

Login successful. (The special user level)

You have logged in to the administrator level.

411

Login successful. (The general user level)

You have logged in to the user level.

420

Connection has been lost.

The connection has been lost.

421

The number of simultaneous connection has been exceeded.

The maximum number of simultaneous connections has been reached, so no further connections can be made.

422

Communication has timed-out.

Communication timed out so the connection was closed.

450

This entry is incorrect.

You cannot currently log in. This may happen for one of the following reasons:
• The user name is not registered.
• The user name is invalid.
• The user ID is wrong.

451

Login prohibited because another user is logged in.

Another user is already logged in. This may happen for one of the following reasons:
• Someone has already logged in with the same user name.
• When the multi-login function is not enabled and someone has logged in through key operations.

452

This command must be used with LL command.

Use the LL command.

10.1 A List of Messages

Advertising
This manual is related to the following products: