Yokogawa Removable Chassis DX1000N User Manual

Page 51

Advertising
background image

1-40

IM 04L41B01-01E

Resetting the Relative Timer

If the event is set to output relay, internal switch, match time timer, or alarm, the

resetting of the timer is not considered a timeout. (The action is not executed even if
the timer is used as an event.)

Loading the Setup

Can be specified as an action only when the event is set to remote control input.
Loads the setup data file, LOAD1.PDL, LOAD2.PDL, or LOAD3.PDL, in the root

directory of the CF card into the DX and updates the DX settings.

You must create a setup file and save it to the CF card in advance.

Event Trigger Operation

When the event is set to output relay, internal switch, or alarm
If the output relay is activated, the internal switch is 1, or the alarm is occurring during

memory sampling, the event trigger is always activated. However, the number of times
the trigger is activated depends on the event data mode (single or repeat).

Time Adjustment

Time adjustment can be specified as an action only when the event is set to remote

control input. The internal clock of the DX is adjusted to the nearest hour through
remote control input.

• Operation When Memory Sampling Is Stopped

Difference from the Nearest Hour Operation
00 min 00 s to 01 min to 59 s

Truncates the minutes and seconds.

Example: 10 hours 01 min 50 s becomes 10 hours 00 min

00 s.

02 min 00 s to 57 min to 59 s

The time is not changed.

58 min 00 s to 59 min to 59 s

Rounds up the minutes and seconds.

Example: 10 hours 59 min 50 s becomes 11 hours 00 min

00 s.

• Operation during Memory Sampling

If the time difference between the time the remote control signal is applied and the

nearest hour is within the preset time, the time is gradually corrected. Otherwise,
the time is corrected immediately. For details, see section 10.1.

On DXs with the /AS1 Advanced Security Option and Release Number 4 or

Later

Event

Conditions for Execution

Output relay, internal switch,

timer, match time timer, and

alarm

When these events occur, their corresponding actions are

performed regardless of the user privilege settings and whether

users are logged in.

User Key

The same as the key operation itself. In setting mode, memory

start cannot be performed.

Event edge switch and event

level switch

The same as the key operations themselves. Even in setting

mode, memory start cannot be performed.

Remote

When a remote control signal is received, the corresponding

action is performed regardless of the user privilege settings

and whether users are logged in. In setting mode, memory start

cannot be performed.

1.6 Event Action and Remote Control Functions (/R1 and /PM1 Options)

Advertising
This manual is related to the following products: