3 data saving function, 3 data saving function -6, Configuration – Yokogawa Removable Chassis DX1000N User Manual

Page 300: Data type, Display data and event data

Advertising
background image

12-6

IM 04L41B01-01E

12.3 Data Saving Function

Configuration

Item

Specifications

Internal memory

Temporarily saves various types of data.

Medium

Flash memory

External storage medium

Medium

CF card (up to 2 GB)

Format

FAT32 or FAT16

Data Type

Item

Specifications

DX data types and file extensions
Data Type

Extension

Notes

Display data

.DAD
.DSD

/AS1, release numbers 4 and later

Event data

.DAE
.DSE

/AS1, release numbers 4 and later

Manual sampled data

.DAM

Screen image data

.PNG

Setup data

.PDL
.PEL

/AS1, release numbers 4 and later

Report data

.DAR

/M1 and /PM1

.xml

/M1 and /PM1, release numbers 4 and later

Custom display setup data

.CDC

Release numbers 3 and later

Change settings log data

.TXT

/AS1, release numbers 4 and later

Display Data and Event Data

Item

Specifications

Internal memory

File storage capacity

400 MB (standard memory; release numbers 4 and later)

Number of files

Up to 400

Operation

FIFO (First In First Out)

Display data

Target

Measurement/computation input channel

Sampling intervals

Determined by the sample rate.

25 ms, 125 ms, 250 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 20

min and 30 min (15 min, 20min, and 30min are only available on releases 3 and later)

An interval that is shorter than the scan interval cannot be set.

Description

Maximum or minimum value per sampling interval

Data size

Measurement input channel data: 4 bytes/data value. Computation channel data: 8 bytes/

data value.

File size

Up to 8 MB

Data format

Binary

Recording

Records data at all times.

Event data

Target

Measurement/computation input channel.

Sampling interval

Select from the available settings between 25 ms to 600 s.

Description

Data per sampling interval

Data size

Measurement input channel data: 2 bytes/data value. Computation channel data: 4 bytes/

data value.

File size

Up to 8 MB

Data format

Binary

Mode

Free: Records data at all times.

Trigger: Starts recording data when a certain event occurs and records for the specified interval.

Combinations of saved data Display data only, event data only, or display data and event data.
File size

See appendix 1.