6.10 Changing the Display Layout, Clearing of the

Waveform at Start, Message Display Direction,

Waveform Line Width, and Grid

This section explains how to change the display layout, waveform line width, and grid. It
also explains how to clear waveforms when memory sampling starts.

For an explanation of these functions, see section 1.4.

Display

RD-MV1000

Press MENU and then select Menu tab > Display > Trend.

RD-MV2000

Press MENU and then select Menu tab > Display > Trend, Bar graph, LCD, Monitor.

Settings

• Trend > Direction

Set the trend waveform display direction to Horizontal, Vertical, Wide, or Split.

• Trend > Trend clear

Setting

Description

On

Clears the displayed waveforms when memory sampling starts.

Off

Does not clear the displayed waveforms when memory sampling starts.

• Trend > Message direction

Sets the message display direction to Horizontal or Vertical. The message direction is

fixed to Horizontal if Trend Direction is set to Vertical.

• Trend > Trend line

Sets the line width of trends in dots (1 to 3).