6 general specifications, Construction, Normal operating conditions – Yokogawa Button Operated MV2000 User Manual

Page 276: Input terminal (input terminal suffix code -1), Input terminal (input terminal suffix code -2)

Advertising
background image

13-14

M-4660

13.6 General Specifications

Construction

Item

Specifications

Material

Case: Aluminum plate (RD-MV2000), metal plate (RD-MV1000)
Bezel: Polycarbonate

Color

Case: Smoke blue (Munsell 4.1PB6.0/4.5 or equivalent)
Bezel: Light gray (Munsell 5.2PB8.2/1.0 or equivalent)

External dimensions

RD-MV1000: 189(W) × 177(H) × 253(D) mm, 189(W) × 177(H) × 259(D) mm

*

RD-MV2000: 307(W) × 273(H) × 254(D) mm , 307(W) × 273(H) × 260(D) mm

*

* With clamp terminals (input terminal suffix code is -1) or pulse inputs (/PM1 option)

Weight

RD-MV1004, RD-MV1006, RD-MV1012: Approx. 3.3 kg, RD-MV1008, RD-MV1024: Approx. 3.5
kg, RD-MV2008, RD-MV2020: Approx. 5.3 kg, RD-MV2010: Approx. 5.2 kg, RD-MV2030: Approx.
5.5 kg, RD-MV2040, RD-MV2048: Approx. 5.6 kg excluding options

Normal Operating Conditions

Item

Specifications

Supply voltage

90 to 132, 180 to 250 VAC

Power supply frequency

50 Hz ± 2%, 60 Hz ± 2%

Ambient temperature

0 to 40°C

Ambient humidity

20 to 80%RH (at 5 to 40°C)

Vibration

10 to 60 Hz, 0.2 m/s

2

Shock

Not allowed

Magnetic field

400 A/m or less (DC and 50/60 Hz)

External noise

Normal mode (50/60 Hz)

DC voltage

The peak value including the signal must be less than 1.2 times the measuring range.

Thermocouple

The peak value including the signal must be less than 1.2 times the measuring thermal
electromotive force.

RTD

50 mV or less

Common mode noise

250 VACrms or less for all ranges (50/60 Hz)

Maximum noise voltage between channels

250 VACrms (50/60 Hz) or less

Installation position

Horizontal
You can tilt the MV by bringing the front legs out.

Warm-up time

At least 30 minutes after power-on

Installation location

Indoors

Operating altitude

2000 m or less

Input Terminal (input terminal suffix code -1)

Item

Specifications

Type

Clamp terminal
Attachable and detachable for each channel
Recommended wire size: 0.08 mm

2

to 1.5 mm

2

(AWG28 to 16)

Input Terminal (input terminal suffix code -2)

Item

Specifications

Type

M4 screw

Advertising
This manual is related to the following products: