13-11

M-4660

Specifications

1

2

3

4

5

6

7

8

9

10

11

12

13

App

Index

Computation Function (including the report function) (/M1)

Item

Specifications

Number of computation channels RD-MV1004, RD-MV1008, RD-MV2008: 12 channels (101 to 112)

RD-MV1006, RD-MV1012, RD-MV1024: 24 channels (101 to 124)
RD-MV2010, RD-MV2020, RD-MV2030, RD-MV2040, RD-MV2048: 60 channels (101 to
160)

Operation

General arithmetic operations: Basic arithmetic, square root, absolute, common logarithm,
natural logarithm, exponential, and power
Relational operations: <, ≤, >, ≥, =, ≠
Logic operations: AND, OR, NOT, XOR
Statistical operations: TLOG, CLOG
Special operations: PRE, HOLD, RESET, CARRY
Conditional operation: [a?b:c]

Computation accuracy

Double-precision floating point for TLOG.SUM and single-precision floating point for all
other computations

Usable data

Channel data

Measurement, computation, and external input channels (/MC1)

Constants

60 constants

Communication input data

RD-MV1000: 24, RD-MV2000: 60

Remote control input status

0/1 (/R1)

Pulse input

Counts the number of pulses (/PM1)

Status input

Internal switch, alarm output relay (/A[ ]), and flags

Rolling average:

Performs moving average on the computed results.

Measure range

–9999999 to 99999999
Decimal place: Zero to four fractional digits

Alarms

High limit, low limit, delay high limit, and delay low limit
Hysteresis: High and low limit alarm: 0.0% to 5.0% of the span.

Display

Same as the measurement channels

Data saving

Same as the measurement channels

Report function

Number of report channels: same as the number of computation channels
Operations: Average, maximum, minimum, sum, instantaneous value
Report types: Hourly, daily, hourly + daily, daily + weekly, daily + monthly

Cu10, Cu25 RTD Input/Three-Wire Isolated RTD Input (/N1)

Item

Specifications

Measurement/display accuracy

Under standard operating conditions

Input Type

Measurement

Range

Accuracy

Guaranteed

Range

Measurement Accuracy

Max.

Resolution

A/D integration time:

16.7 ms or more

A/D integration time:

1.67 ms

Cu10 (GE)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: a = 0.00392 at 20°C
Cu10: a = 0.00393 at 20°C
Cu25: a = 0.00425 at 0°C

–70 to 170°C
–75 to 150°C
–200 to 260°C

–200 to 300°C

–328 to 572°F

–200 to 300°C

* Measuring current i = 1 mA

(0.4% of rdg + 1.0°C)

(0.3% of rdg + 0.8°C)

(0.8% of rdg + 5.0°C)

(0.5% of rdg + 2.0°C)

0.1°C

Input source resistance

1 Ω or less per wire (The resistance of all three wires must be equal.)

Ambient temperature influence (applies when the A/D integration time is 16.67 ms or greater)

±(0.2% of range + 2 digits) or less

Signal source resistance

With a variation of 1 Ω per wire (same resistance for all three wires): ±(0.1% of rdg +
1 digit) or less
With a maximum difference of 40 mΩ between wires: Approx. 1°C