Entering Settings (Launcher)

2.4 Entering Data Logging Conditions

1

2

3

4

5

Index

6

Entering Logging Settings

Procedure

Click the Record tab.

Recording Rate

The logging interval is specified in integral multiples of the scanning interval. An

integer from 1-120 is specified for the recording rate setting. The logging interval is the
product of the integer specified here and the scanning interval, and is shown in the
right of the text box.

1.

Click the Recording rate box and enter an integer value.

Repeat Counts

You can specify the number of times logging is performed.

1.

Click the Repeat counts box and enter the number of times to perform logging.

You must enter a number of 1 or larger.

2.

Select the Repeat counts check box. Logging ends after the specified number of

times.

If the check box is clear, the trigger count is unlimited. In this case, the user must

stop logging manually.

Note

If you stop recording manually while in progress, logging occurs right up to the point where the

operation was stopped.